LBSA
51.2V 105AH LIFEPO4 BATTERY PACK USER MANUAL
www.LBSA.co.za
CAN communication DIP address should setup as the following table.
CAN Communication
Master Packs (#1, #2, #3, #4 set OFF)
#5, #6, #7, #8 set as follows
Slave Packs (#5, #6, #7, #8 set OFF)
#1, #2, #3, #4 set as follows
8
7
6
5
4
3
2
1
One pack
OFF
OFF
OFF
OFF
2 packs in
parallel
OFF
OFF
OFF
ON
1
st
slave pack
OFF
OFF
OFF
ON
3 packs in
parallel
OFF
OFF
ON
OFF
2
nd
slave pack
OFF
OFF
ON
OFF
4 packs in
parallel
OFF
OFF
ON
ON
3
rd
slave pack
OFF
OFF
ON
ON
5 packs in
parallel
OFF
ON
OFF
OFF
4
th
slave pack
OFF
ON
OFF
OFF
6 packs in
parallel
OFF
ON
OFF
ON
5
th
slave pack
OFF
ON
OFF
ON
7 packs in
parallel
OFF
ON
ON
OFF
6
th
slave pack
OFF
ON
ON
OFF
8 packs in
parallel
OFF
ON
ON
ON
7
th
slave pack
OFF
ON
ON
ON
9 packs in
parallel
ON
OFF
OFF
OFF
8
th
slave pack
ON
OFF
OFF
OFF
10 packs in
parallel
ON
OFF
OFF
ON
9
th
slave pack
ON
OFF
OFF
ON
11 packs in
parallel
ON
OFF
ON
OFF
10
th
slave pack
ON
OFF
ON
OFF
12 packs in
parallel
ON
OFF
ON
ON
11
th
slave pack
ON
OFF
ON
ON
13 packs in
parallel
ON
ON
OFF
OFF
12
th
slave pack
ON
ON
OFF
OFF
14 packs in
parallel
ON
ON
OFF
ON
13
th
slave pack
ON
ON
OFF
ON
15 packs in
parallel
ON
ON
ON
OFF
14
th
slave pack
ON
ON
ON
OFF
16 packs in
parallel
ON
ON
ON
ON
15
th
slave pack
ON
ON
ON
ON