background image

13

ENGLISH

ZEPHIRO 1000ST HAZE User manual

 

f

If the haze turns less, and the pump makes noise, switch off the unit immediately 

and check fluid level, fuse, controller interface and power plug. If all of these are 

normal, please connect power again. If problems still continue, please contact the 

supplier.

 

f

When you shut down the machine, it is recommended that you remove any re-

maining fluid inside. Especially when the machine will not be used for a long time. 

It is recommended that you open the tank, remove the fluid hose and place it next 

to the tank in open air.

 

f

After use, let the haze machine cool down before transporting it by the handle. 

Small bits of haze may still be emitted just after the machine is turned off. Let the 

machine cool down for at least 20 minutes and only transport it when the housing 

of the machine reaches a temperature that is comfortable enough to handle. Trans-

porting the machine while it is still hot may cause injuries and permanent damage 

to the internal electronics and heating elements.

11.  SPECIFICATIONS

Heating element

1000 Watt

Warm-up time

Approximately 1,5 Minutes

Tank capacity

2 Liters

Haze output

170m³/Min

Liquid consumption 

200 Min/L (30%) - 120 Min/L (100%)

Control Panel 

Yes (6 buttons with LCD display 2x8 Characters)

DMX connectivity

Yes (3/5 Pin )

DMX controls

Yes (2 Channel - fan speed, output volume )

Flight case

Yes (Included)

Power requirements

220V AC, 50Hz

Internal fuse

10A 250V fast blow 20mm glass

Dimensions

440x215x395 mm

Weight

12 Kg

Packing Size

475x245x420 mm

Packing Weight

13 Kg

Summary of Contents for ZEPHIRO 1000ST HAZE

Page 1: ...Please read this manual carefully and properly take care of it USER MANUAL Leggete questo manuale e conservatelo per future consultazioni MANUALE utente 1000W STAGE HAZE MACHINE ZEPHIRO 1000st HAZE ...

Page 2: ...ment an incorrect operation can cause damages to you and to the unit Take care The SOUNDSATION Team Gentile Cliente Grazie per aver scelto un prodotto SOUNDSATION La nostra missione è quella di offrire ai nostri utenti una vasta gamma di strumenti musicali ed apparecchiature audio e lighting con tecnologie di ultima generazione Speriamo di aver soddisfatto le vostre aspettative e se voleste collab...

Page 3: ...AND SERVICE 14 13 WARNING 14 IMPORTANT SAFETY SYMBOLS The symbol is used to indicate that some hazardous live terminals are involved within this apparatus even under the normal operating condi tions which may be sufficient to constitute the risk of electric shock or death The symbol is used in the service documentation to indicate that spe cific component shall be replaced only by the component sp...

Page 4: ... the room Fresh air needs to be able to enter the room and vaporized fog needs to be able to be drained from the room f f Pay caution with the amount of haze used Only small amounts of haze are re quired to accentuate professional lighting and make the beams visible Do not proceed producing fog when the visibility drops below 2 meters f f The use of haze is not hazardous for people or animals if u...

Page 5: ...efer all servicing to qualified service personnel only Only use accessories attachments or parts recommended by the manufacturer 1 UNBOXING When receiving the machine open its package and check carefully whether the ma chine is damaged or accessories are lost if any problems please contact the supplier When you ll open the package 1 carton you will find the following items f f 1x Haze Machine f f ...

Page 6: ...on dance floors in concerts and more ZEPHIRO 1000ST HAZE is able to produce haze volume of 170 m min thanks to a 1000 Watt heating system a powerful pump and a large tank 2L 4 FRONT PANEL 7 1 2 3 4 5 6 8 9 10 11 12 1 Anti Spill Tank 2 Liquid tank cap 3 Liquid hose with quick connector 4 Fuse 5 Blue LCD Screen 2 Row X 8 Characters 6 Control Panel 6 buttons 7 Haze Output Deflector 8 DMX 5 Pin XLR Ou...

Page 7: ...ice is ready the LCD screen will show Ready Haze message and after that it is possible to start making haze manually by holding down the MAN UAL button on the control panel f f To turn OFF the machine unplug the unit from its power source 6 MAINS CONNECTIONS Please note that power voltage and frequency are the same as the marked voltage and frequency of device when connecting power Wire correspond...

Page 8: ...X is a resilient communication protocol however errors still occasionally occur In order to prevent electrical noise from disturbing and corrupting the DMX control signals a good habit is to connect DMX output of last fixture in the chain to a DMX terminator especially over long signal cable runs 120ohm 1 4 W resistor DMX Terminator The DMX terminator is simply an XLR connector with a 120Ω ohm 1 4...

Page 9: ...n 2 Signal Pin 3 Signal Pin 4 N C Pin 5 N C 3 Pins XLR socket Pin 1 GND Screen Pin 2 Signal Pin 3 Signal 5 Pins XLR socket Pin 1 GND Screen Pin 2 Signal Pin 3 Signal Pin 4 N C Pin 5 N C 3 Pins XLR plug Pin 1 GND Screen Pin 2 Signal Pin 3 Signal 8 CONTROL PANEL ZEPHIRO 1000ST HAZE is equipped with a Control Panel consisting of an LCD display 2 Row X 8 Characters and 6 buttons 1 FUNCTION This button...

Page 10: ...al haze emission timer using buttons The timer range is from 10 to 200 seconds DURATION Pressing two times the Function button when the device shows the main message Ready Haze the display will show DURATION parameter and its relative value as follows Set 10 Duration The Duration Parameter allows to adjust the continuous Haze Output Time using buttons The Duration Parameter range is from 10 to 200...

Page 11: ...meter and its relative value as follows Set 100 Volume This parameter allows to adjust the output of constant Haze quantity from 1 to 100 using buttons Fan Speed Press the Function button till the display shows FAN SPEED parameter and its relative value as follows Set 100 FanSpeed This parameter allows to set the fan speed from 1 to 100 using buttons 9 NOTICES f f This haze machine should be used ...

Page 12: ...again f f In the case of a serious operating problem stop using the unit immediately Never try to repair the unit by yourself Repairs carried out by unskilled people can lead to damage or malfunction Please contact the nearest authorized technical assistance center Always use the same type of spare parts f f Never connect the device to a dimmer pack f f Make sure the power cable in never crimped o...

Page 13: ...ze may still be emitted just after the machine is turned off Let the machine cool down for at least 20 minutes and only transport it when the housing of the machine reaches a temperature that is comfortable enough to handle Trans porting the machine while it is still hot may cause injuries and permanent damage to the internal electronics and heating elements 11 SPECIFICATIONS Heating element 1000 ...

Page 14: ...CENTER Via Enzo Ferrari 10 62017 Porto Recanati Italy In order to send a product to service center you need an RMA number Shipping charges have to be covered by the owner of the prod uct For further information please visit www soundsationmusic com 13 W ARNING PLEASE READ CAREFULLY EU and EEA Norway Iceland and Liechtenstein only This symbol indicates that this product is not to be disposed of wit...

Page 15: ...ERTENZA 26 IMPORTANTI ISTRUZIONI DI SICUREZZA Il simbolo è usato per indicare che in questa apparecchiatura sono presenti alcuni terminali sotto tensione pericolosi anche in condizioni di normale funzionamento che possono costituire rischio di scosse elettriche o di morte Il simbolo viene utilizzato nella documentazione di servizio per indi care che uno specifico componente può essere sostituito e...

Page 16: ...empre che ci sia una sufficiente ventilazione in modo che l aria possa circolare e la nebbia vaporizzata possa essere scaricata dalla stanza di utilizzo del dispositivo f f Prestare attenzione alla quantità di nebbia utilizzata Sono necessarie solo piccole quantità di foschia per accentuare il lighting professionale e rendere i fasci di luce molto più visibili Non continuare con la produzione di f...

Page 17: ...llegamento alla rete elettrica L apparecchio deve essere collegato alla sorgente di alimentazione elettrica del tipo indicato sull apparecchio o descritto nel manuale Un collegamento elettrico non corretto può invalidare la garanzia del prodotto Pulizia Pulire solo con un panno asciutto Non utilizzare solventi come benzene o alcool Manutenzione In caso di guasto o malfunzionamento interrompere imm...

Page 18: ...otente macchina da 1000 Watt con interfaccia DMX Questo dispositivo con la sua emissione continua di foschia è un buon supporto per l illuminazione Può essere utilizzato in molti campi di applicazione per creare atmosfere sottili e migliorare gli effetti visivi dei fasci di luce sulle piste da ballo nei concerti e molto altro ZEPHIRO 1000ST HAZE è in grado di produrre un volume di foschia di 170 m...

Page 19: ...cavo di alimentazione in dotazione deve essere collegato a una presa elettrica dotata di messa a terra Una volta collegata la macchina per la nebbia inizia a riscaldarsi e il display LCD mostrerà il messaggio Warming ad indicare che il dispositivo è in preparazione per poi essere utilizzato Questo processo può richie dere fino a 1 5 minuti f f Quando il dispositivo è pronto lo schermo LCD mostrerà...

Page 20: ...no 3 è positivo S 3 Poli XLR Piedino 1 MASSA Piedino 2 DMX Piedino 3 DMX USCITA INGRESSO Uso dei 3 Piedini nei Connettori XLR per DMX ATTENZIONE I fili non devono entrare in contatto l uno con l altro altrimenti i dispositivi non funzioneranno affatto o non funzioneranno correttamente 20 1 Terminatore DMX DMX è un protocollo di comunicazione elastico tuttavia si potrebbero verificare oc casionalme...

Page 21: ...R a 5 poli è necessario utilizzare un cavo adattatore o farlo da soli seguendo la corri spondenza di cablaggio tra gli standard di spina e presa a 3 e 5 poli 5 Pins XLR plug Pin 1 GND Screen Pin 2 Signal Pin 3 Signal Pin 4 N C Pin 5 N C 3 Pins XLR socket Pin 1 GND Screen Pin 2 Signal Pin 3 Signal 5 Pins XLR socket Pin 1 GND Screen Pin 2 Signal Pin 3 Signal Pin 4 N C Pin 5 N C 3 Pins XLR plug Pin 1...

Page 22: ...ul display verrà visualizzato il parame tro INTERVAL ed il suo relativo valore nel seguente modo Set 10 Interval Il parametro Interval consente di regolare il timer per l intervallo di emissione foschia utilizzando i pulsanti Il range di valori per questo timer è compreso tra 10 e 200 secondi DURATION Premendo due volte il pulsante Function dalla videata principale Ready Haze il display visualizze...

Page 23: ...lezionato 1 VOLUME Premere il pulsante Function fino a che sul display non venga visualizzato il para metro VOLUME ed il suo relativo valore nel seguente modo Set 100 Volume Questo parametro consente di impostare la quantità costante di emissione foschia scegliendo da una percentuale di 1 fino al 100 Il valore è selezionabile tramite i pulsanti Fan Speed Premere il pulsante Function fino a che sul...

Page 24: ... mento f f Tutte le macchine per la nebbia possono avere condensa o umidità intorno al deflettore di uscita e tutte emettono costantemente una piccola quantità di foschia durante o dopo l uso f f Tutte le macchine per la foschia hanno cicli di riscaldamento e raffreddamento Quando la temperatura interna scende al minimo la pompa si accende automa ticamente e inizia a riscaldarsi Al termine del ris...

Page 25: ...di rimuovere il liquido rimanente all in terno soprattutto quando la macchina non verrà utilizzata per un lungo periodo Si suggerisce di aprire il serbatoio rimuovere il flessibile del fluido e posizionarlo vicino al serbatoio all aria aperta f f Dopo l uso lasciare raffreddare la macchina prima di trasportarla utilizzando la maniglia Piccoli spruzzi di foschia possono ancora essere emessi subito ...

Page 26: ...Per poter inviare un prodotto al centro di assistenza è necessario un numero di RMA Le spese di trasporto devono essere coperte dal proprietario del prodotto Per ulteriori informazioni visitate il sito www soundsationmusic com 26 A VVERTENZA LEGGETE ATTENTAMENTE solo per UE e SEE Norvegia Islanda e Liechtenstein Questo simbolo indica che il prodotto non deve essere smaltito con i rifiuti domestici...

Page 27: ...viene importato nella UE da FRENEXPORT SPA Via Enzo Ferrari 10 62017 Porto Recanati Italy www soundsa tionmusic com Soundsation is a registered trademark of FRENEXPORT SPA Italy Soundsation è un marchio di fabbrica registrato della FRENEXPORT SPA Italy ...

Page 28: ...www soundsa tionmusic com Ver 1 0 Jan 2018 ...

Reviews: