8CH Strobe
0-9
No function
10-200
Conventional strobe
201-239
Random strobe
240-255
No function
9CH Dimmer
0-255
0-100%
10CH Red
0-255
0-100%
11CH Green
0-255
0-100%
12CH Blue
0-255
0-100%
13CH White
0-255
0-100%
14CH Control
(When value
is between
20-99, the
extended
function 1CH-
5CH works)
0-19
No function
20-39
Pan/Tilt scan fast
40-59
Pan/Tilt scan slow
60-79
Sound1
80-99
Sound2
100-119
120-139
140-159
160-179
180-199
200-219
Reset
220-239
240-255
10. TROUBLESHOOTING
Phenomenon
Solution
Fixture cannot start to work
1. Check if the power fuse burnout
Fixture light normally, but no re-
sponding to the DMX controller
1. Check if the DMX start address is correct
2. Check if the XLR signal cable was damaged
Fixture work intermittently
Check if the fan work well, Whether dust
blocked fan and fan nets
11. Maintenance
When the lens have fracture and other damage, it should be replaced in time. When the
fixture can’t start to run, please check if the fuse is burnout. If it is so, please install the
fitted corresponding specification fuse (5x20mm T3A / 250V).
12
ENGLISH
TWILIGHT 60 ENDLESS User manual