9
ENGLISH
Quartetto Series User manual
3-Pin XLR
Pin 1: GND
Pin 2: DMX -
Pin 3: DMX +
OUTPUT
INPUT
DMX use of 3-Pin XLR Connectors
DMX Termonator
Unit 1
Unit 2
Last Unit
DMX 512
Connect fixtures using shielded 2-conductor twisted pair cable with 3-pin XLR male to
female connectors. The shield connection is pin 1, while pin 2 is Data Negative (S-), and
pin 3 is Data positive (S+).
CAUTION: Wires must not come into contact with each other; otherwise the
fixtures will not work at all, or will not work properly.