NOTE

When routing the cable, make sure the end with the
closed tip terminals (male pins) is toward the power
supply and the end with the open tip terminals (female
pins) is toward the light head.

4.

Insert the pins on each end of the conductor cables into

the AMP connectors. Each end of these cables has a factory
crimped pin on each of the three wires, see Figure B.

NOTE

It is important to follow the correct color code when
inserting the pins into the AMP connectors.

5.

Connect the cables to the strobe light heads.

6.

Next, plug the other end of the cable into the light head

output socket on the strobe power supply, see Figure A.  The
location of the connector for each light head attached to the
unit will be determined by the flash pattern selected (see fig-
ure E).

7.

Plug the Flash Control Wire Harness assembly into the

Flash Control Input Socket on the strobe power supply. Con-
nect the wires from Flash Control Wire Harness assembly to
the switch control panel  (see “Flash Control Wire Harness
Assembly” section).

8.

Plug the Power Wire Harness assembly into the Power

Input Socket.  Connect the strobe power supply to the power
source to complete the installation (see “Power Wire Harness
Assembly” section).

FLASH CONTROL WIRE HARNESS ASSEMBLY

The Flash Control Wire Harness assembly consists of an AMP
3 pin connector with 3 wires: green, blue and yellow (see Fig-
ure C or Figure E).  The green wire controls the strobe light
outlets 1 and 4.  The blue wire controls the strobe light outlets
2 and 3.  For a standard Quad flash installation, the yellow
wire is not used and can be removed.

NOTE

If the special flash options (WarpFlash™, Quint,
Double) are to be used, the yellow wire is needed and
the blue and green wires take on different functions,
see “Special Mode” section.

The Flash Control Harness assembly must be connected to
the control socket located on the Q450 Strobe Light power
supply, see Figure E and Figure A.  Use 18 gauge wire to
extend the control harness wires to a customer supplied switch
to complete the installation.

POWER WIRE HARNESS ASSEMBLY

The power wire harness is connected to the power input socket
located on the Q450 Strobe Power supply, see Figure A and
Figure E.  The power wire harness assembly consists of red
and black wires (see Figure D) that power the strobe power
supply (see Figure A) and a violet wire that controls the day/
night (high/low) intensity feature of the power supply (see Fig-
ure G).

The high/low intensity feature allows the strobe lights of the
system to be switched into low power or reduced intensity.
This feature is useful for night time use.  When the violet wire
is powered with (+) 12 volts, the power supply is switched to
low intensity.  When power is removed, the power supply
switches to high intensity mode.  If the high/low feature is not
wanted, simply do not install the violet wire, see Table for
exception.

Figure C.  Flash Control Wire Harness

Figure D.  Power Wire Harness

Use 18 gauge wire to extend the red and black wires and the
violet high/low control wire (if used) to a customer supplied
control switching system, see Figures F and G.

Figure E

1

2

3

RED WIRE (+) in Hole #1

BLACK WIRE (-) in Hole #2

VIOLET WIRE (HIGH/LOW) in Hole #3

2 WIRE POWER-INPUT
HARNESS ASSEMBLY

8 INCH HIGH/LOW WIRE
ASSEMBLY WITH AMP PIN
FACTORY CRIMPED ON

1

2

3

1

2

3

1

2

3

1

2

3

1

2

3

1

2

3

4

SIMULTANEOUS FLASH

ALTERNATING FLASH

ALTERNATING FLASH

SIMULTANEOUS FLASH

CONTROL

POWER

BLUE (+)

GREEN (+)

YELLOW (+)

VIOLET

BLACK (-)

RED (+)

RIDGE
(indicates location of hole #1)

YELLOW WIRE - HOLE #1
GREEN WIRE - HOLE #2
BLUE WIRE - HOLE #3

AMP 3 PIN
CONNECTOR HOUSING