Soundoff Signal PINNACLE EPL7PD C Series Quick Start Manual Download Page 2

NOTICE: 

Installers and users must comply with all applicable federal, state and local laws regarding use and installation of warning devices.

Improper use or installation may void warranty coverage.

To review our Limited Warranty Statement & Return Policy for this or any SoundOff Signal product, visit our website at 

www.soundoffsignal.com/tech-services/returns/

.

If you have questions regarding this product, contact 

Technical Services

, Monday - Friday, 8 a.m. to 5 p.m. ET at 

1.800.338.7337

 (press #4).

  Questions or comments that do not require immediate attention may be emailed to 

[email protected].

ENHANCING SAFETY THROUGH INNOVATION

EPL7PD(x)C_EPL7000  0121

1.800.338.7337 / www.soundoffsignal.com

REPLACEMENT PARTS & ACCESSORIES

PMB3BKT- Replacement Permanent Mount Bracket (each)
PMB3BRKT- Replacement Permanent Mount Bracket (kit)
PMB3TDC- EPL7000 Replacement Clear Dome

TECHNICAL SPECIFICATIONS

Overall Dimensions:

14.25”L x 8.27”W x 2.93”H

Flash Patterns:

29 flash patterns

Input Voltage Range:

10 - 16 Vdc

Current Consumption:

2 Amps (Avg) - 4 Amps (Max)

# of LEDs:

 24 Generation 3 LEDs

Operating Temperature:

-40º to +65º C

Cord Length:

125.75”

Flash Patterns

Number/Name

Modules Affected

1. Warp

Alternating

2. Quad

3. Quad2

4. Quint

5. Double2

6. Warp 1, 2, 3

7. Progressive

8. Q-Switch™

9. Intercycle

10. Warp

Whole Bar

11. Quad

12. Quad2

13. Quint

14. Double2

15. Warp 1, 2, 3

16. Progressive

17. Warp

Diagonal

18. Quad

19. Quad2

20. Quint

21. Double2

22. Warp 1, 2, 3

23. Progressive

24. Q-Switch

25. Intercycle

26. Rotator

27. Cycle 1

Random

28. Cycle 2

29. Cruise

Whole Bar

ELECTRICAL:

PATTERN CHANGE

While the lightbar is operational, touch the 
WHITE WIRE to 10-16Vdc and hold for longer 
than 1.5 seconds.  All light engines will steady 
burn, turn off, and then start flashing the next 
pattern on the list.  Release the WHITE WIRE 
after the bar resumes flashing.  If multiple 
pattern changes are required, the power must 
be cycled after every change.  

The

 PINNACLE Mini Lightbar features non-

volatile memory and will recall last pattern 
used. 
Selected pattern will remain the default once 
turned off and can be changed by changing the 
flash pattern before powering off.

ACTIVATE/DEACTIVATE CRUISE

While the lightbar is operational, touch the 
WHITE WIRE to 10-16Vdc for less than one 
second.  The lightbar will enter cruise mode.  
The lightbar will remain in cruise mode unless 
power is cycled or the WHITE WIRE is touched 
to 10-16vDC for less than one second again.

FOLLOW DIAGRAM BELOW FOR ELECTRICAL CONNECTIONS

RED WIRE: Connect through a switch and fuse to 10-16Vdc

BLACK WIRE: Connect to a good reliable ground (-)

WHITE WIRE: Momentary, connect to 12V (+)

EPL7000 MINI LIGHTBAR PERMANENT MOUNT

RED

BLACK

WHITE

5 AMP  FUSE

+12 Vdc

PINNACLE 

LIGHTBAR