ENFSLXSS 11.14
COLOR SWAP
This function is only valid for dual and tri-color light modules and can only be changed when the light module is in a flashing mode (disabled for single color modules and when light module is operating in cruise or steady ON functions). When
the light is flashing, momentarily connect the white or yellow wire to ground for >2S and <3S (light will go steady high, steady low, off) then release. The light module will switch between Color Swap OFF and Color Swap ON. When Color
Swap is OFF, the 1st color will flash 1st on a dual/tri color pattern. When Color Swap is ON, the 2nd color will flash 1st on a dual/tri color pattern.
SIMULTANEOUS/ALTERNATE
This function can only be changed when the LED module is in a flashing mode (disabled in cruise or steady ON functions) and only has an effect when at least 2 LED modules have the green sync wire connected together. When the light is
flashing, momentarily connect the white or yellow wire to ground for >3S and <4S (light will go steady high, steady low, off, steady high) then release. The light module will switch between Simultanous and Alternate each time this sequence
is done. To have light modules flash simultaneously, both light modules need to be set to the same sequence type (Set-Up Table). To have light modules flash alternately, the light modules need to be set to different sequence types (Set-Up
Table).
ADVANCE PATTERN
Flash pattern can only be changed when the LED module is in a flashing mode (disabled in cruise or steady ON functions). When the light is flashing, momentarily connect the white or yellow wire to ground for >250mS and <1S (light will go
steady high) then release. The flash pattern will advance to the next pattern. If the light module was at the last pattern, the pattern will reset to the 1st pattern.
BACKUP PATTERN
This function is only valid when the LED module is in a flashing mode (disabled in cruise or steady ON functions). When the light is flashing, momentarily connect the white or yellow wire to ground for >1S and < 2S (light will go steady high,
steady low) then release. The flash pattern will backup to the previous pattern. If the light module was at the first pattern, the pattern will change to the last pattern on the list.
PATTERN RESET
This function is only valid when the LED module is in a flashing mode (disabled in cruise or steady ON functions). When the light is flashing, momentarily connect the white or yellow wire to ground for >5S and <6S (light will go steady high,
steady low, off, steady high, steady low, off) then release. The flash pattern will reset to the 1st pattern in the list.
FACTORY RESET
This function is only valid when the LED module is in a flashing mode (disabled in cruise or steady ON functions). When the light is flashing, momentarily connect the white or yellow wire to ground for >6S and <7S (light will go steady high,
steady low, off, steady high, steady low, off, steady high) then release. The LED module will reset to: pattern=1, Function Table=1, Color Swap=OFF, Simultaneous.
SETUP TABLE
SECONDS
USER INTERFACE
FROM
TO
VISUAL FEEDBACK
ACTION TAKEN
0
1
STEADY-HIGH (60%)
FORWARD ONE PATTERN
1
2
STEADY-LOW (30%)
BACKWARD ONE PATTERN
2
3
OFF
COLOR SWAP (OFF OR ON )
3
4
STEADY - HIGH (60%)
SEQUENCE TYPE:
SIMULTANEOUS OR ALTERNATE
4
5
STEADY - LOW (30%)
SEE FUNCTION TABLE
5
6
OFF
RESET TO PATTERN 1
6
7
STEADY-HIGH (60%)
FACTORY RESET (PATTERN 1, COLOR SWAP:
OFF, SIMULTANEOUS)
SEPARATE COLOR CONTROL: OFF
If held longer than 7 seconds, the light will go back to flashing the current