![Soundoff Signal ETSWDAS02 Installation & Operation Instructions Download Page 2](http://html.mh-extra.com/html/soundoff-signal/etswdas02/etswdas02_installation-and-operation-instructions_1335258002.webp)
DIRECTIONAL ARROW SWITCH
PAGE 1
PRODUCT SPECIFICATIONS
Pin #
Wire Color
Function
1
Red
+10-30 Vdc Power Input
2
White / Red
Master / Ignition switch (0u = Stand by)
3
Black
(-) Ground
4
NA
Not populated
Pin #
Wire Color
Function (All OVdc Active High)
1
Blue
LEFT Arrow Indicator Output Control
2
Brown
CENTER Arrow indicator Output Control
3
Green
RIGHT Arrow Indicator Output Control
4
Yellow
WARNING 1 Output Control
5
Pink
WARNING 2 Output Control
6
Red/Black
N/A
CN1 (2x2, Power Input Connector)
CN2 (2x3, Control Output Connector, Low Current: 0.25A Max)*
Input Voltage:
+10-30 Vdc
Polarity:
Negative Ground
Reverse Polarity Protection: Yes
Transient Protection:
Yes
Operating Temperature:
-40C to +85C
Current Draw:
0.8 Amps
Standby Current:
Zero Amps
+Vin Fuse:
5 Amps ATO
Dimensions
166mm x 22mm x 45mm (6.55" x 0.88" x 1.76")
170 mm (6.7") w/ Mounting Bracket
Shipping Weight
.65 lbs
Electrical
Mechanical
WIRE COLORS/USES
DIRECTIONAL ARROW SWITCH
PAGE 5
Product Configuration Mode:
By holding down the Left and Warning Buttons together for 2 seconds, product configuration mode can
be entered. The unit will make a long “beep”, and all of the buttons will turn green when product
configuration mode has been entered.
Changing the level of brightness on the red LEDs:
The level of brightness can be changed (high, low, and off ) by pressing the Left button in product
configuration mode.
Changing level of sound:
The volume of the speaker can be changed (high, low, and off ) by pressing the Right button in product
configuration mode.
Changing between Center output options:
Which wires the Center button applies power to can be changed in the product configuration mode by
pressing the Center Button.
When the Yellow LED in the middle is lit, the unit will apply power to the Brown Wire
When the second and fourth LED’s are lit, the unit will apply power to the Blue and Green wires.
* Must NOT exceed a total of 0.25 Amp for any combination of active outputs.