Soundoff Signal ETSWDAS02 Installation & Operation Instructions Download Page 2

DIRECTIONAL ARROW SWITCH

PAGE 1

PRODUCT SPECIFICATIONS

Pin #

Wire Color

Function

1

Red

+10-30 Vdc Power Input

2

White / Red

Master / Ignition switch (0u = Stand by)

3

Black

(-) Ground

4

NA

Not populated

Pin #

Wire Color

Function (All OVdc Active High)

1

Blue

LEFT Arrow Indicator Output Control

2

Brown

CENTER Arrow indicator Output Control

3

Green

RIGHT Arrow Indicator Output Control

4

Yellow

WARNING 1 Output Control

5

Pink

WARNING 2 Output Control

6

Red/Black

N/A

CN1 (2x2, Power Input Connector)

CN2 (2x3, Control Output Connector, Low Current: 0.25A Max)*

Input Voltage:

+10-30 Vdc

Polarity:

Negative Ground

Reverse Polarity Protection: Yes

Transient Protection:

Yes

Operating Temperature:

-40C to +85C

Current Draw:

0.8 Amps

Standby Current:

Zero Amps

+Vin Fuse:

5 Amps ATO

Dimensions

166mm x 22mm x 45mm (6.55" x 0.88" x 1.76")
170 mm (6.7") w/ Mounting Bracket

Shipping Weight

.65 lbs

Electrical

Mechanical

WIRE COLORS/USES

DIRECTIONAL ARROW SWITCH

PAGE 5

Product Configuration Mode:

By holding down the Left and Warning Buttons together for 2 seconds, product configuration mode can 
be entered.  The unit will make a long “beep”, and all of the buttons will turn green when product 
configuration mode has been entered.  
 

Changing the level of brightness on the red LEDs:

The level of brightness can be changed (high, low, and off ) by pressing the Left button in product 
configuration mode.

Changing level of sound:

The volume of the speaker can be changed (high, low, and off ) by pressing the Right button in product 
configuration mode.

Changing between Center output options:

Which wires the Center button applies power to can be changed in the product configuration mode by 
pressing the Center Button.  

When the Yellow LED in the middle is lit, the unit will apply power to the Brown Wire

When the second and fourth LED’s are lit, the unit will apply power to the Blue and Green wires.

*  Must NOT exceed a total of 0.25 Amp for any combination of active outputs.

Summary of Contents for ETSWDAS02

Page 1: ...arning mode press the warning button once The Current Warning Mode Option is designated by the yellow LEDs 1 Warning Mode setting 1 is designated by yellow LED 1 2 Warning Mode setting 2 is designated by yellow LED 2 3 Warning Mode setting 3 is designated by yellow LED 3 4 Warning Mode setting 4 is designated by yellow LED 4 5 Warning Mode setting 5 is designated by yellow LED 5 6 Warning Mode set...

Page 2: ...s Electrical Mechanical WIRE COLORS USES DIRECTIONAL ARROW SWITCH PAGE 5 Product Configuration Mode By holding down the Left and Warning Buttons together for 2 seconds product configuration mode can be entered The unit will make a long beep and all of the buttons will turn green when product configuration mode has been entered Changing the level of brightness on the red LEDs The level of brightnes...

Page 3: ...Reliable Ground Red Constant power 12v or 24v White w Red Switch Master Ignition switch Pressing the Left Button will apply power to the Blue wire Left Arrow Direction and display the left arrow pattern on the yellow LED s Pressing the Center button will apply power to the Brown Wire Center Arrow Direction and display the center out pattern on the yellow LED s Pressing the Right button will apply ...

Page 4: ...reen Wire Right Arrow Direction Connect to Blue wire of the Traffic Master Please see page 10 for instructions on how to change between center output options Configure to apply power to the brown wire Center Option 1 Note If you are using optional wiring then the Dark Green and Blue wires must swap Blue Wire Left Arrow Direction Connect to the Blue wire of the Traffic Master Green Wire Right Arrow...

Reviews: