background image

DE2-EAMSAA200   11.16  Pg. 5

1.800.338.7337 / www.soundoffsignal.com

DE2-EAMSAA200 
200W COMPACT SIREN W/PA FUNCTION

-TESTING AFTER INSTALLATION-

After installation, test all the functions of A200 including the horn 

operation or footswitch if used, to ensure that it is operating properly. 

All effective sirens and horns produce loud sounds (120 dB) that may 

cause permanent hearing loss. Always minimize your exposure to 

siren sound and wear hearing protection. After installation and testing 

is complete provide a copy of this manual to all operating personnel.

-MAINTENANCE-

Your Compact siren has been designed to provide trouble free 

service. In case of difficulty, see the Troubleshooting Guide. A primary 

cause of failure is shorted or open wires. The majority of the short/

open circuits have been found where wiring passes through firewalls, 

roofs, etc. If difficulty persists, contact the factory for troubleshooting 

advice or return instructions, maintain a complete parts inventory 

and service facility at the factory and will repair or replace (at the 

factory’s discretion) any unit found to be defective under normal 

use and in warranty. Any attempt to service a unit in warranty 

by anyone other than a factory authorized technician without the 

express written consent of the factory, will void the warranty. Units 

out of warranty can be repaired at the factory on either a flat rate or 

parts/labor basis. Contact the factory service department for details 

and return instructions. Our company is not liable for any incidental 

charges related to the repair or replacement of a unit unless 

otherwise expressly agreed to in writing by the factory.

PROBLEM

CAUSE

REMEDY

No speaker output

A. Siren not connected
B. Fuse missing/open
C. Speaker wires/speaker shorted

A. Check siren wiring & connections
B. Replace fuse
C. Check siren wiring & connections

Fuse Blows

Power connections reversed

Check power connections

No output from speaker, tones heard 

inside siren amplifier module

A. Speaker not connected, open 
circuit in speaker wiring
B. Speaker failure

A. Check speaker wiring

B. Replace speaker

Siren tones volume too low/garbled

A. Low voltage to siren amplifier

B. Defective speaker/high 
resistance wiring

A. Check wiring for bad connections.  
Check vehicle charging system
B. Check speaker wiring/replace speaker

TROUBLE SHOOTING GUIDE

Summary of Contents for Armada A200

Page 1: ...NSTALLER Make sure to read and understand all instructions and warnings before proceeding with the installation of this product Ensure the manual and all warning cards are delivered to the end user of this equipment TECHNICAL SPECIFICATIONS Overall Dimensions Remote Switch Panel Amplifier Microphone 2 1 H x 1 W x 3 6 D 2 5 H x 5 8 W x 6 3 D 1 0 H x 1 5 W x 4 0 D Input Voltage 11 16Vdc negative gro...

Page 2: ...h the carrier stating the extent of the damage if the siren has been damaged Carefully check all enveloped shipping labels and tags before removing or destroying them MOUNTING AMPLIFIER INSTALLATION 1 The A200 amplifier is waterproof It may be mounted under the vehicle s hood in the trunk under the rear deck under the front seat or in the equipment cabinet It must be installed in an adequately ven...

Page 3: ...e may be considered to use When using two 100W speakers they must be connected in parallel and in phase For instance the pin 1 of the speaker A should combine the pin 1 of the speaker B to the SPKR COM position of the connector The other two leads should connect to SPKR position of the connector c Door Park Siren Off input This input accepts only ground input to deactivate the siren tones If conne...

Page 4: ...2 SPKR COM SPKR 16 GA 15A 20 GA 12V BATTERY Microphone red wire 16 GA 20 GA 20 GA 20 GA 20 GA Microphone white wire Microphone blue wire Microphone green wire 18 GA 18 GA 100W SIREN SPEAKER 100W SIREN SPEAKER OFF SWITCH IGN CONTROL 12V DC S4 VEHICLE HORN SWITCH S1 S2 S3 Microphone black wire AUX S2 S3 S1 S4 AUX SWITCH SCROLL SWITCH SIREN OFF SWITCH A200 SIREN PA AMPLIFIER Figure 1 Wiring Diagram ...

Page 5: ...scretion any unit found to be defective under normal use and in warranty Any attempt to service a unit in warranty by anyone other than a factory authorized technician without the express written consent of the factory will void the warranty Units out of warranty can be repaired at the factory on either a flat rate or parts labor basis Contact the factory service department for details and return ...