Soundelux U99 User Manual Download Page 2

www.bockaudio.com

Power Supply and Cable

The Bock Audio P-251 full linear power supply features simple shunt B+ regulation and 
active current source for the heater. The outputs and cable pinouts are shown in the 
table at right.

Specifications

Patterns:  

 

 

Remote continuously variable omni 

 

 

 

 

through cardioid and figure 8

Frequency Range: 

 

10 Hz to 18 kHz, ±2 dB

Sensitivity: 

  33 

mv/Pa

Equivalent Noise: 

 

19 dB (“A” weighted), 29 dB (unweighted)

Distortion vs. SPL @ 1 kHz:  

(increasing distortion is non-exponential, nearly linear, and primarily 2nd harmonic)

 

 

 

 

112 dB = 0.5% THD 

 

 

 

 

118 dB = 1% THD

 

 

 

 

129 dB = 2% THD

Impedance: 

 

 

200 Ohms true transformer balanced

Recommended load: 

 

2K Ohms

Dynamic range:   

 

99 dB (max SPL-”A”noise)

S/N (94 dB-noise): 

 

75 dB (“A” weighted), 65 dB (unweighted)

Capsule size: 

 

 

1” diameter, dual symmetrical backplate K67 type

Tube type: 

 

 

New Old Stock EF732

Dimensions: 

 

 

2” dia x 9” oal (50 x 228 mm)

Weight:   

 

 

1 lb 9.3 oz (1.58 lbs) = 716 g

Shipping weight:  

 

12 lbs

Power Supply:   

 

P251 true linear, factory wired 115v or 230v operation

Safety

Pin #

Output

1

audio (-)

2

audio (+)

3

pattern (if applicable)

4

heater (5.1v typical)

5

B+ (120v typical)

6

ground

case

shield

•  CAUTION: Shock Hazard: Do not open microphone when connected to 

power source. No user serviceable parts inside. Refer failed units to 
qualified service personnel.

•  VORTICHT: Shock gefar: Bitte nicht daf mikrofon offen wenn es 

eingeschaltet ist einen stoppkontakt.

•  Keine zu wartenden Teile im Inneren. Beziehen gescheitert Einheiten 

qualifiziertem Service-Personal.

•  ATTENCIONE: Choc hazard: N’ouvrez pas le microphone quand il y a 

un connectionne avec un source d’electricity. Aucune pièce réparable 
par l’utilisateur. Référer unités échoué à un personnel qualifié.

•  ATTEZIONE: Riscchio di scossa: Non aprire il microfono quando e 

attacato al’eletricita. Non contiene parti riparabili. Riferimento unità 
riusciti a personale qualificato. 

•  Read the instructions.
•  Keep these instructions.
•  Heed all warnings.
•  Follow all instructions
•  Do not use this apparatus near water.
•  Clean only with dry cloth.
•  Do not block any ventilation openings. Install in accordance with the 

manufacturer’s instructions.

•  Do not install near any heat source such as radiators, heat registers, 

stoves, or other apparatus (including amplifiers) that produce heat.

•  Do not defeat the safety purpose of the polarized or grounding-type 

plug. A polarized plug has two blades with one wider than the other.

•  Protect the power cord from being walked on or pinched particularly 

at plugs, convenience receptacles, and the point where they exit 
from the apparatus.

•  Only use with attachments/accessories specified by the 

manufacturer.

•  Refer all servicing to qualified service personnel. Servicing is 

required when the apparatus has been damaged in any way, such 
as power-supply cord or plug is damaged, liquid has been spilled 
or objects have fallen into the apparatus, the apparatus has been 
exposed to rain or moisture, does not operate normally, or has been 
dropped.

•  Soundelux USA U99
•  UL 62368-2
•  EN 62368-1
•  Part 10004702 v201210

Reviews: