AdvAncEd SEttinGS
AnALOG OUtPUt
the analog outputs enable you to connect soundear®3 to
Building Management systems (BMs) or to communicate
with other devices that are compatible with analog out-
puts.
nOtE!
the SoundEar®3 must be provided with 24vdc
through the screw terminal for the analog outputs to func-
tion. Please find an overview and description of the various
outputs on the back of the device.
nOtE!
the two analog outputs share a ground connection.
24 VDC/150 mA
USB Log/
config.
SoundBuster
Power
5 VDC/
PC data
Ext. mic.
Power
24 VDC
Analogue 0-10V/
Outputs 4-20 mA
3 4 5
+ -
Out 1
GND
Out 2
1 2
24 VDC/150 mA
USB Log/
config.
SoundBuster
Power
5 VDC/
PC data
Ext. mic.
Power
24 VDC
Analogue 0-10V/
Outputs 4-20 mA
5 4 3 2 1
- +
Out 2
GND
Out 1
Model 300, 310 and XL
Model 320
you can record up to two individual mea-
surements simultaneously, one per analog
output.
in the drop-down menu, you can choose
between seven different values for each
output.