Sound Performance Lab 2376 Owner'S Manual Download Page 8

8

24/96 AD Converter 2376

Connections

Input: SYNC INPUT

The SYNC input allows you to feed an external signal into 
the converter to control the sample rate. Connect an S/P-DIF 
output from your master source (e.g. sound card) to the 
SYNC input. The 2376 is not equipped to accept Word Clock 
for synchronization.
The yellow SYNC LOCK LED illuminates when a valid sync 
signal is present at the SYNC input, and the converter is 
automatically synchronized to the external sample rate.
The internal oscillators are automatically disabled when an 
external clock signal is present to prevent interference. If 
the sync signal is no longer present (e.g. in the case of a 
dropout), the converter automatically reverts to the sample 
rate selected via the buttons (see page 9).

Additional input with single-channel devices

If the 24/96 AD Converter is installed in a single-channel 
SPL device such as the GainStation 1, Channel One or Track 
One, the second channel of the stereo converter can be 
used via the additional analog AD converter input on the 
device‘s rear panel.  This  allows  you  to  „daisy-chain“ two 
preamps or channel strips through one converter, or route 
any other single-channel analog signal to the converter‘s 
second channel. For additional information please see the 
manual for the SPL device you are upgrading.

Double S/P-DIF output: RCA and optical

The converted signal is routed  in  parallel  to the RCA  and 
optical outputs. The digital signal is transferred in profes-
sional S/P-DIF format without sample rate data in the status 
block.
We recommend that you check the documentation on your 
receiving device to ensure that it can process the profes-
sional S/P-DIF format (some devices only accept consumer 
format). If your receiving device does not identify the 
sample rate, it most likely needs the status-block data 
and does not automatically recognize the incoming sample 
rate.

Inputs & Outputs

Summary of Contents for 2376

Page 1: ...Model 2376 Owners Manual 24 96 AD Converter Internal stereo AD converter module ...

Page 2: ...inuously strives to improve its products and reserves the right to modify the product described in this manual at any time without prior notice This document is the property of SPL and may not be copied or reproduced in any manner in part or fully without prior authorization by SPL SPL electronics GmbH Sohlweg 55 41372 Niederkruechten Germany Tel 49 0 2163 983 40 Fax 49 0 2163 983 420 Email info s...

Page 3: ...Safety instructions 4 Product features 4 Packing list 5 Installation general instructions adapter plate 5 Installation step by step 6 Connections inputs and outputs 8 Operation 9 Technical specifications 10 Warranty 11 Contents ...

Page 4: ...r clock The converter can be synced to other digital devices via the SYNC input If a valid signal is present the converter automatically conforms to the sample rate received at the SYNC input A yellow LED illuminates to display a valid sync signal The internal oscillators are automatically disabled when an external clock signal is present to prevent interfe rence An extremely effective voltage sta...

Page 5: ... of the respective SPL device and touching the unit s casing Disconnect the power cable as well as any other cables from the SPL unit Handle the converter module with care avoiding contact with the components Hold the module by the panel or the edges of the circuit board only Do not use force or exert excess pressure when connecting the module to the device Adapter plate Most converter ready SPL d...

Page 6: ...ed Loosen the screws and remove the cover of the option slot on the device s rear panel Step 2 Remove the strap holding the cable from the inside of the option slot cover You may have to carefully cut through the drop of silicone Installation Steps 1 2 example shown Channel One Socket Plug Socket ...

Page 7: ...ble from the device into the slot on the converter module The plug only fits one way into the slot Step 4 Without turning it insert the module into the device circuit board up and fasten it using the screws from the option slot cover Congratulations Your new converter module is now ready for operation Installation ...

Page 8: ...ingle channel SPL device such as the GainStation 1 Channel One or Track One the second channel of the stereo converter can be used via the additional analog AD converter input on the device s rear panel This allows you to daisy chain two preamps or channel strips through one converter or route any other single channel analog signal to the converter s second channel For additional information pleas...

Page 9: ...ter module allows you to select between the four most common sample rates 44 1 48 88 2 and 96 kHz Using the 44 1 48 button select one of the two basic sample rates out 44 1 kHz in 48 kHz The x2 button doubles these sample rates to select 88 2 or 96 kHz respec tively Sample Rate ...

Page 10: ...Hz Dynamic range 104 dB A weighted THD N 1 dBFS 1 kHz 95 dB Frequency response 48 kHz 10 Hz 22kHz 0 2 dB Jitter average 700 Hz 100 kHz 300 ps Power consumption 15 V max 94 mA Power consumption 15 V max 5 mA Dimensions W x H x D 100 x 27 x 76 mm 3 94 x 1 06 x 3 in Weight 74 g 2 6 oz ...

Page 11: ...undperformancelab com or in the USA or Canada at www spl usa com The warranty period begins on the date of purchase The warranty is non transferable Repairsorreplacementsdonotextendthewarranty period This warranty does not apply if the product was not purchased from an authorized SPL dealer repairs are required due to normal wear and tear the product has been abused misused or improperly maintaine...

Page 12: ...12 24 96 AD Converter 2376 Owners Manual 24 96 AD Converter Model 2376 ...

Reviews: