© 1999-2019 SOTA Instruments Inc.
Page 6 of 7
|
www.sota.com
The Water O
3
zonator Model WOZ3 Manual
WATER DISINFECTION TESTS
Tests by two independent laboratories proved the effectiveness of the ozone generated
by a SOTA Water Ozonator in killing the following virulent pathogens:
ELECTRICAL SPECIFICATIONS
POWER REQUIREMENTS
12 Volts DC @ 1.5 Amps,
Tip or Center Positive.
Caution
: Exceeding the voltage rating or reverse connection may result in injury or
unit failure. This will
void
the warranty.
OPTIONAL POWER INPUT
To operate the ozone generator from a 12 Volt DC source such as an automobile
battery, or an appropriate solar panel, purchase a Universal Power Cord with
POSITIVE
tip.
OUTPUT SPECIFICATIONS
Greater than 108 mg/Hr O
3
@ 1.5 LPM. Measured using an Ozone-in-Air GM
Anseros Ozone Analyzer, Model Ozomat GM 6000-RT. Ozone concentration is 1.8
Gamma (mg/l or ug/ml) @ 0.5 LPM.
Pump outputs 0.5 PSI pressure, 2 LPM (2000 cc/min) volume.
OZONE GENERATOR CONSTRUCTION
Uses Fused Quartz Glass ozone chamber. With normal use, the chamber should last
several years.
Escherichia coli (E coli)
Salmonella spp (typhoid fever)
Pseudomonas aeruginosa
Shigella spp
Staphylococcus aureus
Proteus mirabilis
Klebsiella spp
Candida spp