Soshine 12.8V24AH Instruction Manual Download Page 4

DOC: 

IFR12.8V24AH(4S4P)M5       

                                     

Page 

4

 Of 

Pages

4

 

Battery Specification

 

No.

 

Items

 

Specifications

 

Remark

 

4.1

 

Type

 

LiFePO4

 

Lithium iron phosphate

 

Nominal Capacity

 

24Ah

 

4.2

 

 

Capacity

 

Minimum Capacity

 

23.5Ah

 

0.2C Standard discharge & new battery status

 

4.3

 

 

Nominal Voltage

 

12.8V

 

Means operation voltage

 

4.4

 

Operation Voltage

 

10.8~14.2V

 

 

4.5

 

Absolute Charging 

Voltage

 

14.2

 

±0.03V

 

By standard charge method, 3.55V max for unit 
cell

 

4.6

 

Discharge Cut-off 

Voltage

 

10.8V

 

2.7V for unit cell

 

4.7

 

Voltage

 

 

Delivery Voltage

 

12.8~13.2V

 

Within 10 days from factory

 

4.8

 

Standard Charging 

Method

 

0.2C  constant  current,  14.2V  constant  voltage  charge  to  14.2V,  continue  charging  till 
current decline to

 

0.01C

 

4.9

 

0.2C(Standard)

 

4.8A

 

Standard charge, charge time about 7.5h(Ref)

 

4.10

 

0.5C

 

12A

 

Rapid charge, charge time about: 3h(Ref)

 

4.11

 

Charge Current

 

0.5C(Maximum)

 

12A

 

For continuous charging mode.

 

Ambient 

temperature 25°C

 

4.12

 

0.2C(Standard)

 

4.8A

 

constant current discharge to 10.8V

 

4.13

 

0.5C

 

12A

 

For continuous discharge mode.

 

Ambient 

temperature 25°C

 

4.14

 

Discharge Current 

 

2C(Maximum)

 

24A

 

The surface temperature of the cells 

60°C 

 

4.15

 

Impedance

 

Battery Internal

 

<60mΩ

 

Internal resistance measured at AC 1KH

new 

battery after 50% charge new battery

 

4.16

 

Absolute Charge

 

0~45°C

 

60

±

25%R.H.

 

4.17

 

Absolute Discharge

 

-20~60°C

 

60

±

25%R.H.

 

4.18

 

Standard Charging 

Temperature

 

25±2°C

 

4.19

 

Operation Temperature 

and Relative Humidity 

Range

 

Standard Discharging 

Temperature

 

25±2°C

 

Battery Surface Temperature

 

Charge at a very low temperature such as below 
0°C,  will  be  get  a  lower  capacity  and  reduce 
cycle life of the battery.

 

Beyond the temperature range of charge and 
discharge, the battery must stop working.

 

4.20

 

Storage Temperature 

for a Long Time

 

-20~25°C

 

60

±

25% R.H.

 

Do not store for more than a year. It must be 
charged once in storage for half a year.                                        

 

4.21

 

Self-discharge Rate 

Per Month

 

≤3.5%

 

New battery after stored more than 3 months.

 

4.22

 

Shipment Capacity

 

30% SOC 

(≥7.2Ah)

 

 

4.23

 

Weight

 

About 2.9

±

0.3kg

 

 

4.24

 

Cycle

 

>1000-2000 times

 

80% D.O.D.

 

4.25

 

Output Terminals

 

M5

 

 

4.26

 

Maximum Number of 

Concatenations

 

Four in series

 

The dropout voltage between batteries 

0.1V

 

 

Summary of Contents for 12.8V24AH

Page 1: ...DOC IFR12 8V24AH 4S4P M5 Page 1 Of 9 Pages LiFePO4 Battery 12 8V24AH Instruction Manual Soshine International www soshine com cn summer soshine com cn...

Page 2: ...01C 240mA 2 3 4 Short circuit Protection Disconnect When a short circuit occurs the battery is disconnected from the over current 2 3 5 Over current Protection According to 4 11 and 4 14 the battery...

Page 3: ...quality assurance 2 9 Battery heat diffusion In the design of the electric box the heat diffusion of the battery should be fully considered Soshine shall not be responsible for the quality assurance...

Page 4: ...5C 12A For continuous discharge mode Ambient temperature 25 C 4 14 Discharge Current 2C Maximum 24A The surface temperature of the cells 60 C 4 15 Impedance Battery Internal 60m Internal resistance me...

Page 5: ...rotection Overcharge protection delay 0 5S 2S 5 8 Protective voltage 2 0 0 1V 5 9 Restore voltage 2 70 0 1V 5 10 Over discharge protection delay 10 200mS 5 11 Over discharge protection Over current pr...

Page 6: ...s essentially flat meaning that a 20 charged battery will be providing nearly the same output voltage as an 80 charged battery This prevents any issues caused by the voltage sag common to lead acid as...

Page 7: ...FR12 8V24AH 4S4P M5 Page 7 Of 9 Pages 8 Battery Initial Dimensions and Label 8 1 Dimensions 8 2 Battery label No Item Unit mm 1 Battery length L 181 0 2 2 Battery width W 167 0 2 3 Battery height H 77...

Page 8: ...hould stop using the battery Any violation of the requirements shall be exempted from Soshine s quality guarantee responsibility which based on product sales contract and this specification 11 Storage...

Page 9: ...s specification shall be agreed by both parties 16 CAUTIONS IN USE To ensure proper use of the battery please read the manual carefully before using it Handling When charging and discharging do not re...

Reviews: