11) Verify the two red LEDs of the two configured Control Units (UG) are not blinking.
Otherwise refer to §8 MAINTENANCE.
12) Test the triggering of the alarms on cable 2 of the 1st set-up Control Unit (UG) and on cable 1
of the 2
nd
set-up Control Unit (UG) by generating alarm on the fence.
The Red LED turns ON and the Buzzer goes ON on both configured Control Units (UG).
Wait 10 sec between 2 triggering of alarm.
13) Close the cover of the first configured Control Unit (UG).
14) For the next Control Unit (UG), not configured, repeat steps 1) to 10).
15) Launch the site configuration via the MAXIBUS III Hub. (See manual NT297)
Configure the detection zones with the graphic software. (See manual NT296)
6
SETTINGS
The different functions are made to adapt the G-Fence system to all kind of installations according to
the type of support.
The available settings are:
Manual setting of the sensitivity of all sensors on the same cable.
Manual setting of the sensibility of one sensor.
Setting of alarm detection on 1 or 2 sensors.
Setting of the time Window of the alarm detection between sensors (only active with alarm
detection on 2 sensors)
Response time for the cutting of the cable from 5 sec to 30 sec.
1
st
configured UG
2
nd
configured UG
Next not configured UG
Cable 1
Cable 2
Cable 1
Cable 2
Cable 1
Cable 2