Features and Specifications
Specifications
17
Table 1.5
Specifications for XHR 1000 W Series Supply with RS-232 Interface Installed (7.5 V to 60 V)
Models
7.5-130
20-50
33-33
40-25
60-18
Program Resolution
Voltage
Current
OVP
1.2mV
18.3mA
1.2mV
3.1mV
7.1mA
3.1mV
5.1mV
4.7mA
5.1mV
6.2mV
3.6mA
6.2mV
9.3mV
2.6mA
9.3mV
Program Accuracy
1
Voltage
Current
OVP
1.
Apply accuracy specifications according to the following voltage program accuracy example:
Set a model 20-50 power supply to 10 volts.
The expected result will be within the range of 10 volts ± 50mV ± 0.12% of the set voltage of 10 volts.
10mV
±0.12%
500mA
±0.1%
80mV
75mV
±0.12%
250mA
±0.1%
200mV
75mV
±0.12%
165mA
±0.1%
330mV
75mV
±0.3%
140mA
±0.15%
400mV
150mV
±0.25%
120mA
±0.1%
600mV
Readback Resolution
Voltage
Current
1.2mV
18.3mA
3.1mV
7.1mA
5.1mV
4.7mA
6.2mV
3.6mA
9.3mV
2.6mA
Readback Accuracy
1
Voltage
Current
30mV
±0.12%
500mA
±0.1%
75mV
±0.12%
250mA
±0.1%
75mV
±0.2%
165mA
±0.15%
75mV
±0.3%
140mA
±0.15%
150mV
±0.25%
120mA
±0.1%
Summary of Contents for RS232-XFR