1.1 EC declaration of conformity

By af

fi

 xing the CE mark to the unit the manufacturer declares that the WPC5 

conforms to the following relevant safety regulations:
-  

EC low voltage directive

 

73/23/EEC, as amended by 93/68/EEC 

-  

EC electromagnetic compatibility directive 

  

89/336/EEC version 92/31/EEC version 93/68/EEC

Conformity has been veri

fi

 ed and the corresponding documentation and 

the EC declaration of conformity are kept on 

fi

 le by the manufacturer. 

1.2 General instructions 

It is essential that you read this!

These installation and operating instructions contain basic instructions 
and important information regarding safety, installation, commissioning, 
maintenance and the optimal use of the unit. Therefore these instructions 
must be read completely and understood by the installation technician/
specialist and by the system user before installation, commissioning and 
operation of the unit. 
The valid accident prevention regulations, VDE regulations, the regula-
tions of the local power utility, the applicable DIN-EN standards and the 
installation and operating instruction of the additional system components 
must also be observed. The controller does not under any circumstances 
replace any safety devices to be provided by the customer!
Installation, electrical connection, commissioning and maintenance of the unit 
may only be carried out by specialists who possess the appropriate training.
For the user: Make sure that the specialist gives you detailed information on 
the function and operation of the controller. Always keep these instructions 
in the vicinity of the controller.

1.3 Explanation of symbols

Failure to observe these instructions can result in danger to life 
from electric voltage.

Danger

Danger

Failure to observe these instructions can result in serious damage 
to health such as scalding, or even life-threatening injuries.

Caution

Failure to observe these instructions can result in destruction of 
the unit or the system, or damage to the environment.

Caution

Information which is especially importation for the function and 
optimal use of the unit and the system.

Safety instructions

1

1

Summary of Contents for WPC 5

Page 1: ...1 Heat pump controller WPC 5 Installation and operating instructions Read carefully before installation commissioning and operation...

Page 2: ...mentvalues Menu1 6 17 Statistics Menu 2 7 1 Operating hours 7 2 Average T 7 3 Heat output 7 4 Graphic overview 7 5 Error messages 7 6 Reset clear 7 18 18 18 18 18 18 Operating times Menu 3 8 1 Time da...

Page 3: ...ions the regula tions of the local power utility the applicable DIN EN standards and the installation and operating instruction of the additional system components must also be observed The controller...

Page 4: ...original spare parts and accessories Use of the device for other than its intended purpose Operation above or below the limit values listed in the specifications Force majeure Changes additions to or...

Page 5: ...oisture condensation permitted Other specifications and dimensions Housing design 2 part ABS plastic Installation methods Wall installation optionally panel installation Overall dimensions 163mm x 110...

Page 6: ...al error conditions and Voltage Interlock Resetting to previously selected values or factory settings A wide range of additional functions are available and or planned Network integration with expansi...

Page 7: ...y temperature limiters scalding protectors etc and must therefore be provided Caution 4 2 3 Hydraulic variant program 1 Heat pump with heating circuit 1 5 Hydraulic variant program 2 Heat pump with bu...

Page 8: ...lower part of the hou sing up to the selected position and mark the 3 mounting holes Make sure that the wall surface is as even as possible so that the housing does not become distorted when it is sc...

Page 9: ...t hand side Caution Fig 3 2 1 Caution The cables being connected to the unit must not be stripped by more than 55mm and the cable jacket must reach into the housing just to the other side of the strai...

Page 10: ...in the left hand terminal compartment Terminal Connection for Jumper terminal block S S1 Sensor 1 outdoor S2 Sensor 2 heating circuit S3 Sensor 3 not used S4 Sensor 4 glycol flow S5 Sensor 5 glycol r...

Page 11: ...l neutral conductors N The PE protective conductor must be connected to the PE metal termi nal block Low voltage max 12VAC DC connection in the left hand terminal compartment Terminal Connection for J...

Page 12: ...onnect all neutral conductors N The PE protective conductor must be connected to the PE metal termi nal block Low voltage max 12VAC DC connection in the left hand terminal compartment Terminal Connect...

Page 13: ...terface cable for the bus connection is then routed from the WPC5 basic unit to the specific EMC expansion module This connection is made on the terminals provided for this purpose ensure proper polar...

Page 14: ...try or to exit a menu If applicable there will be a request for confirmation as to whether the changes which have been made should be saved The function of each of the other three keys 4 is shown in t...

Page 15: ...ent temperature values with explanations see 6 Function control of the system with operating hours etc see 7 Operatingtimesforheatingcircuitand hot water setting the clock see 8 Operatingtimesforheati...

Page 16: ...10 Menu 6 Protective functions if adaptations are necessary see 11 Menu 7 Special functions if additional changes are necessary see 12 Finally menu 4 2 under operating mode Manual should be used to te...

Page 17: ...the measurement value then there may be a defective or incorrect temperature sensor Caution Measurement values Menu 1 6 6 If the cables are too long or the sensors are not placed optimally the result...

Page 18: ...under 7 1 7 3 as a bar graph Various time ranges are available for comparison The two left hand keys can be used to page through the data 7 5 Error messages Menu 2 5 Resetting and clearing the individ...

Page 19: ...t accurately on the controller Please note that the clock continues to run for about 24 hours if the mains voltage is interrupted and after that has to be reset Caution Caution Times that are not spec...

Page 20: ...iods can be specified for each weekday and copied over to the following days Setting range Two time ranges for each day of the week Default setting Mon Sun 06 00 22 00 Note See 10 for the associated t...

Page 21: ...each day of the week Default setting Mon Sun off Note See 10 for the associated temperature settings This function does not provide complete protection against Le gionella because the controller is de...

Page 22: ...nto account In the operating mode One the hot water charging is switched on continuously regardless of the set times and in the operating mode Off the domestic hot water charging is switched off compl...

Page 23: ...elay R4 is switched on first Please also note that high pressure faults may occur if the storage tank charging pump or if applicable the heating circuit pump is not also switched on at the same time F...

Page 24: ...in nighttime mode If this value is exceeded at outdoor sensor S1 during the nighttime mode times the controller automatically switches the heating circuit off Sum mer mode If the outdoor temperature d...

Page 25: ...design temperature with the minimum outdoor temperature Example Design temperature of the heater 60 C Flow at lowest outdoor temperature according to heating demand calculation 12 C The intersection...

Page 26: ...ordingly during the nighttime operating hours In this manner primarily at night but also during the day when no one is at home the room temperature is lowered thus saving energy Example A day correcti...

Page 27: ...2 C to 20 C default setting 10 C 10 14 Domestic hot water heating for low rate period Menu 5 14 do mestic hot water heating low rate period With the value set here it is possible for example to ensure...

Page 28: ...1 6 2 2 A frost protection function can be activated for the heat pump If the glycol return temperature drops below the value set here the control ler switches the heat pump glycol pump compressor of...

Page 29: ...ere must be water circulation in the storage tank and piping system by means of other additional energy sources and control units The anti Legionella function is switched off at delivery When heating...

Page 30: ...unpredictable errors The settings in this menu should only be made by a specialist 12 2 Heat quantity Menu 7 2 A simple heat metering function via S4 and S5 for basic system control can be activated...

Page 31: ...kes you back to the previous value so you can look at the selected setting again or adjust it if desired Pressing the esc more than once takes you back to the selection mode thus cancelling the commis...

Page 32: ...here even if there is a demand Setting range from 0 to 30 minutes default setting 10 minutes The settings under this menu item and its four submenus should only be made by a specialist since they hav...

Page 33: ...ustments if neces sary 1 Measurement values 2 Statistics 3 Times 5 Settings 8 Menu lock 9 Service values To block the other menus select Menu lock on To enable the menus again select Menu lock off Set...

Page 34: ...Menu 9 Service values can be used for remote diagnosis by a specialist or the manufacturer in the event of an error etc Caution Enter the values at the time when the error occurs e g in the table The...

Page 35: ...at the temperature at the glycol return is was below the frost protection temperature set in menu 6 2 Means that the maximum tempe rature is was below the maximum heating circuit temperature set in me...

Page 36: ...working on the unit switch off the power supply and secure it against being switched on again Check for the absence of power Danger Danger Only use the supplied spare fuse or a fuse of the same desig...

Page 37: ...37...

Page 38: ...see menu 12 7 6 To protect against loss of data record any statistics and data that are particularly important to you see 7 at regular intervals The operating hours displayed in the Statistics menu sh...

Page 39: ...39...

Page 40: ...ated with the greatest possible care the possibility of incorrect or incomplete information cannot be ex cluded Subject as a basic principle to errors and technical changes Notes SOREL GmbH Mikroelekt...