The Fresh water controller FWC5 facilitates ef

fi

 cient use and function control of your 

fresh water system. The device is impressive most of all for its functionality and simp-
le, almost self-explanatory operation. For each step in the input process the individual 
entry keys are assigned to appropriate functions and explained. The controller menu 
contains headwords for the measured values and settings, as well as help texts or 
clearly-structured graphics. 

Important characteristics of the FWC5:

- 0 - 10V output for speed control
- Simple viewing of the current measurement values
- Analysis and monitoring of the system by means of statistical graphics,etc.
- Extensive setting menus with explanations
- Menu block can be activated to prevent unintentional setting changes
- Resetting to previously selected values or factory settings

B.2  About the controller

Description of controller

-  Fresh water controller FWC
-  replacement fuse 2A slow-blow
-  Installation and operating instructions FWC
Optionally contained depending on design/order:
-  Pt1000 temperature sensor and Vortex Flow Sensor (TFS)

B.3  Scope of supply

B.4  Disposal and pollutants

The unit conforms to the European RoHS directive 2002/95/EC for the restriction of 
the use of certain hazardous substances in electrical and electronic equipment.

Caution

The unit must not under any circumstances be disposed of with ordinary 
household refuse.  Dispose of the unit only at appropriate collection 
points or ship it back to the seller or manufacturer.

Summary of Contents for FWC 5

Page 1: ...Fresh water controller FWC 5 Installation and operating instructions Read carefully before installation commissioning and operation...

Page 2: ...16 2 2 Operating hours circ 16 2 3 Heat output 16 2 4 Graphic overview 16 2 5 Message log 16 2 6 Reset clear 16 3 Display mode 17 3 1 Schematic 17 3 2 Overview 17 3 3 Alternating 17 4 Operating modes...

Page 3: ...utility the applicable DIN EN standards and the installation and operating instruction of the additional system components must also be observed The controller does not under any circumstances replac...

Page 4: ...ies Use of the device for other than its intended purpose Operation above or below the limit values listed in the specifications Force majeure A 5 Warranty and liability Changes additions to or conver...

Page 5: ...ons and dimensions Housing design 2 part ABS plastic Installation methods Wall installation optionally panel installation Overall dimensions 163mm x 110mm x 52mm Aperture installation dimensions 157mm...

Page 6: ...ics etc Extensive setting menus with explanations Menu block can be activated to prevent unintentional setting changes Resetting to previously selected values or factory settings B 2 About the control...

Page 7: ...ng the hydraulic system and does not claim to be complete The controller does not replace safety devices under any circumstances Depending on the specific application additional system components and...

Page 8: ...ch the electronics when doing so 4 Hold the lower part of the housing up to the selected position and mark the 3 mounting holes Make sure that the wall surface is as even as possible so that the housi...

Page 9: ...switched on again Check for the absence of power Electrical connections may only be made by a specialist and in compli ance with the applicable regulations Do not use the controller if the housing sh...

Page 10: ...s no contact resistance Position the sensor precisely in the area to be measured Only use immersion pipe mounted or flat mounted sensor suitable for the spe cific area of application with the appropri...

Page 11: ...nd terminal compartment Terminal Connection for S1 Primary return S2 Circulation S3 Storage middle S4 Primary flow S5 VFS hot water VFS yellow S6 VFS flow l min VFS white VFS 5V DC VFS brown jumper te...

Page 12: ...error is present Entries are made using four keys 3 4 which are assigned to different functions depending on the situation The esc key 3 is used to cancel an entry or to exit a menu If applicable ther...

Page 13: ...enu 4 2 under operating mode Manual should be used to test the switch outputs with the consumers connec ted and to check the sensor values for plausibility Then switch on automatic mode The first time...

Page 14: ...han ges at critical points For diagnosis in the event of an error E 4 Menu sequence and menu structure The graphics or overview mode appears when no key has been press for 2 min utes or when the main...

Page 15: ...r If the cables are too long or the sensors are not placed optimally the result may be small deviations in the measurement values In this case the display values can be compensated for by making entri...

Page 16: ...ating hours HW Display of operating hours of the hot water pump connected to the controller Display of operating hours of the circulation pump connected to the controller 2 2 Operating hours circ 2 3...

Page 17: ...electing Exit display mode Display mode 3 Display mode 3 1 Schematic In graphics mode the selected hydraulic systems are depicted with the measured temperatures and operating states of the connected c...

Page 18: ...f by pressing a key with no regard to the current temperatures and the parameters which have been set The measured temperatures are also shown to provide an overview and function control The high effi...

Page 19: ...ow Min Setpoint temperature at the mixer in the primary flow The setpoint temperature in the primary heat circuit when the flow rate is at its max Settings range 62 C bis 90 C Default setting 70 C 5 4...

Page 20: ...om 00 00 to 23 59 Default 06 00 to 22 00 5 7 Hysteresis Hysteresis for thermostat function By setting the hysteresis value the heating of the storage tank can be adjusted If the temperature of the Tse...

Page 21: ...mode of the circulation Set the mode of circulation in this menu When the mode Request is active the circulation pump is switched on after a corre sponding withdrawal of water has occured In mode Peri...

Page 22: ...h can also be copied to other days Settings range Off 00 00 to 23 59 h Default 06 00 22 00 h The menu item Circulation period is only available while the mode Periods is active Caution In periods not...

Page 23: ...ttings can be made for each individual sensor in steps of 0 5 C Offset S1 S6 per setting range 10 C 10 C Default O C 6 2 Sensor calibration Caution Settings are only necessary in special cases at the...

Page 24: ...Default 2 sec 6 5 2 Pause factor Set a value to multiply the calculated pause time with e g a value of 1 would use the calculated pause time 0 5 would half the pause time and 4 quadruple the calculate...

Page 25: ...la because the controller is dependent on sufficient energy being fed in Special functions With the AL function activated the controller makes it possible to heat the storage in selectable time period...

Page 26: ...d to determine the minimum voltage to switch the pumnp off Settings range 0 to max 1 5V Default 0 7V 6 7 Speed control This function should be activated and parametrised by a specialist only The speci...

Page 27: ...The menus listed below remain completely accessible despite the menu lock being activated and can be used to make adjustments if necessary 1 Measurement values 2 Analysis 3 Display mode 8 Menu lock 9...

Page 28: ...emote diagnosis by a specialist or the manufacturer in the event of an error etc The menu can be closed at any time by pressing esc Caution Enter the values at the time when the error occurs e g in th...

Page 29: ...elect the language for the menu guidance This is queried automatically during initial commissioning The choice of languages may differ however depend ing on the device design Language selection is not...

Page 30: ...or info symbol Possible error messages Sensor x defective Time date Notes for the specialist Means that either the sensor the sensor input at the controller or the connecting cable is was defective Re...

Page 31: ...by a specialist Befo re working on the unit switch off the power supply and secure it against being switched on again Check for the absence of power Only use the supplied spare fuse or a fuse of the s...

Page 32: ...or incomplete information cannot be excluded Subject as a basic principle to errors and technical changes Notes Hydraulic variant set Commissioned on Commissioned by FWC5_Englisch_130113 indd Manufac...

Reviews: