SOR 1510 Installation Instructions Manual Download Page 1

Form 451 (05.18) ©SOR Inc. 

1/8

The SOR

®

 1510 Level Switch mounts into the side of a vessel. Electric switching action is 

provided by the float moving a magnet into the field of a hermetically sealed reed switch 
capsule.

The unit may be mounted for either high or low liquid level alarm by rotating the switch 
body to the proper position. The body wrench flats provide for ease of rotation and proper 
positioning. See decal on housing.

Before Installation of the Level Switch:

   Inspect the unit for any shipment damage.

  Check for mechanical clearance of 

 

the float. Float must move freely without binding throughout its stroke. 

  Use an acceptable thread compound when installing unit to ensure a leak-free fit and to 

avoid thread galling.

  To achieve required function, install the unit according to the nameplate instructions 

shown here.

NOTE: If you suspect that a product is defective, contact the factory or the SOR Representative 
in your area for a return authorization number (RMA). This product should only be installed by 
trained and competent personnel.

1510 

Side Mounted 

Level Switch

General Instructions

NC - indicates 

circuit is closed

Registered Quality System to ISO 9001

Design and 

specifications are 

subject to change 

without notice. 

For latest revision, go to 

www.SORInc.com

Table of Contents

Installation ...................................... 3
SIL Installation Instructions .................. 3
Float Attachment ............................... 3
Dimensions ..................................... 4
Electrical Connection .......................... 5
Special Conditions ............................. 5
Wiring for DPDT Relay ........................ 6
ATEX and IECEx Marking Details ............ 6
Declaration of Conformity .................... 7
Troubleshooting ................................ 8
Replacement Parts ............................ 8

rench flats provide for ease of rotation and proper 

maage.

THIS SIDE UP

N.C. @ LOW LEVEL

THIS SIDE UP

N.C. @ HIGH LEVEL

THIS SIDE UP

N.C. @ HIGH LEVEL

THIS SIDE UP

N.C. @ LOW LEVEL

Nameplate Position

for Low Level Alarm

Nameplate Position

for High Level Alarm

Summary of Contents for 1510

Page 1: ...meplate instructions shown here NOTE If you suspect that a product is defective contact the factory or the SOR Representative in your area for a return authorization number RMA This product should only be installed by trained and competent personnel 1510 Side Mounted Level Switch General Instructions NC indicates circuit is closed Registered Quality System to ISO 9001 Design and specifications are...

Page 2: ...andle for actuation at the desired length The unit may be mounted in any of the following installation arrangements 1 1 2 NPT half coupling No full coupling 2 NPT full coupling Use in conjunction with 2 x 1 1 2 NPT bushing as required 2 NPT pipe tee Use in conjunction with 2 x 1 1 2 NPT bushing as required Optional flanged mounting Optional chamber mounting Linear mm inches Drawing 0098636 REMOTE ...

Page 3: ...he shaft Float Attachment Series 1500 with Flange Safety Integrity Level SIL Installation Requirements The SOR pressure switches have been evaluated as Type A safety related hardware To meet the necessary installation requirements for the SIL system the following information must be utilized Proof Test Interval shall be one year Units may only be installed for use in Low Demand Mode Products have ...

Page 4: ... model number Linear mm inches Drawing 0390760 177 8 7 00 55 6 2 19 14 3 0 56 79 0 REF 3 11 31 5 1 24 MAX 53 8 2 12 FLOAT TRAVEL 22 2 WRENCH FLATS 0 87 FLOAT 1 1 2 NPTM PROCESS CONNECTION OR FLANGE MOUNTING NOT SHOWN BODY 1 2 NPTF ELECTRICAL CONNECTION WIRE LEADS 457 2 18 00 MIN LENGTH COLOR CODED AND MARKED 44 5 WRENCH FLATS 1 75 1 NOTES 1 ACTUATE DEACTUATE POINTS VARY OPERATES 56 4 SATISFACTORIL...

Page 5: ...e permanently attached leads must be suitably protected against mechanical damage and terminated in a suitable junction box or terminal facility Ensure that the wiring conforms to all applicable local and national electrical codes and install unit s according to relevant national and local safety codes Electrical connection is free wire leads with a 1 2 NPT F conduit connection Use two wrenches on...

Page 6: ... 1 2007 04 IEC 60079 11 2011 IEC 60079 25 2010 02 IEC 60079 0 2004 IEC 60079 11 1999 ATEX Listing Information Drawing 0720554 Manufacturer s Registered Trademark Product Type Identification Product Model Identification For Type 1510 Level Switches equipped with DPDT relays a wiring schematic and pin position schematic is shown below When the 1510 is actuated the coil will energize and make both NO...

Page 7: ...ectric Switches SOR Inc 14685 West 105th Street Lenexa Kansas 66215 2003 5NITED 3TATES OF MERICA December 18 2017 4 8 IRECTIVE 5 QUIPMENT NTENDED FOR USE IN 0OTENTIALLY XPLOSIVE TMOSPHERES 4 8 ARKING X ARKING II 1 G Ex ia IIC Ga Ex ia IIC Ga 4 d 4A d OR 4 d 4A d OR 4 4A 4 4A II 2 G Ex db IIC Ga Gb Ex db IIC Ga Gb 4 d 4A d OR 4 d 4A d OR 4 4A 4 4A EC Type Examination Certificate Baseefa06ATEX0271X I...

Page 8: ... float Replace Liquid specific gravity too low Float stem bound up or dirty Clean Part Number Description 3130 052 316SS Float Assembly 3130 106 W9 SPST Hermetically Sealed Switch Capsule 3130 245 W1 SPDT Hermetically Sealed Switch Capsule 3130 259 W1 SPDT Switch Conduit Connection Assembly CK Option Only 3130 107 L9 SPST Hermetically Sealed Switch Capsule 3130 244 L1 SPDT Hermetically Sealed Swit...