SOPEX Innovations Pte Ltd
INSTALLATION INSTRUCTIONS
•
The installer and/or maintenance personnel must verify the
floodlight’s
certification code is
compatible with the environmental and authorised conditions of the site.
•
Check the power rating label to ensure the floodlight is suitable for the electrical main supply.
•
All inadequate and wrong installation or usage will render the warranty void.
•
Ensure power is turned off before installation or troubleshooting. Do not open any part of the
floodlight when it is energised.
•
The floodlight has one power cable entry at the junction box that is fitted with an ATEX and IECEx
approved M20 cable gland for unarmoured cable of diameter 11.0mm to 15.0mm. Second cable
gland or glands of other sizes are options sold separately.
•
Open the junction box by unscrewing the 4 screws on the cover.
•
Use a 3 core power cable that is compatible with the cable gland size.
•
Strip the outer sheath at the connecting end of the cable to expose the 3 insulated wires.
•
Insert the power cable through the gland until the outer sheath appears through the cable gland
bore inside the junction box.
•
Using a torque wrench spanner, tighten the outer nut of the gland with 32.5Nm installation torque
to properly seal the cable in the gland.
•
Strip the insulation at the tip of the 3 insulated wires to expose the conductors for connection.
•
Connect the 3 insulated wires to the terminal block inside the junction box according to their
respective positions: Live (L - brown), Neutral (N - blue) and Protective Earth (PE - Yellow/Green).
•
The terminal block is able to receive wires with cross section up to 4mm
2
. Ensure the bare copper of
the wires are fully inserted into the terminals and the screws are sufficiently tightened.
•
Close the junction box cover and tightening the 4 screws firmly.
SPECIAL CONDITION FOR SAFE USE
When operated at ambient temperature below -20°C, the tempered glass cover of the
floodlight becomes more brittle and can only withstand impact energy of 1J. Please handle with
care in low temperature environment.
TEMPERATURE CLASSIFICATION
Ambient Temperatures
-40°C to +30°C
-40°C to +40°C
-40°C to +50°C
SXF8011W
T6 and T80°C
T5 and T100°C
SXF8011N
T6 and T80°C
T5 and T100°C
SXF8012W
T6 and T80°C
T5 and T100°C
T4 and T135°C
SXF8012N
T6 and T80°C
T5 and T100°C
T4 and T135°C
SXF8013W
T6 and T80°C
T5 and T100°C
T4 and T135°C
SXF8013N
T6 and T80°C
T5 and T100°C
T4 and T135°C
Insulated wire
Outer nut of
cable gland
Junction Box
Outer sheath of
power cable
Page 3 of 4