5-12-7. B Sub Contrast Adjustment
Adjustment Method:
1) Select B SUB CONT from the FOR FACTORY MODE.
2) Connect oscilloscope between TP715 (+) and TP710 (–).
3) Adjust so that the signal level G stands at the specified value
using the
R
and
r
keys on the remote controller.
Specified value:
3.8
±
0.1 V
Adjustment location:
Monitor board
5-12-8.
γ
1 Adjustment
Adjustment Method:
1) Select Gamma1 from the FOR FACTORY MODE.
2) Connect oscilloscope between TP714 (+) and TP710 (–).
3) Adjust so that the signal level H stands at the specified value
using the
R
and
r
keys on the remote controller.
Specified value:
2.1
±
0.15 V
Adjustment location:
Monitor board
5-12-9.
γ
2 Adjustment
Adjustment Method:
1) Select Gamma2 from the FOR FACTORY MODE.
2) Connect oscilloscope between TP714 (+) and TP710 (–).
3) Adjust so that the signal level I stands at the specified value
using the
R
and
r
keys on the remote controller.
Specified value:
3.6
±
0.15 V
Adjustment location:
Monitor board
5-12-10. VCO Free Run Adjustment
Adjustment Method:
1) Select VCO Free Run from the FOR FACTOR MODE.
2) Connect frequency counter between TP508 (+) and TP504 (–).
3) Adjust so that the reading on the counter stands at the specified
value using the
R
and
r
keys on the remote controller.
Specified value:
15,734
±
50 Hz
Adjustment location:
Monitor board
5-12-11. V POS Adjustment
Adjustment Method:
1) Input mono scope signal from the NTSC pattern generator.
2) Select PLL/V POS from the FOR FACTORY MODE.
3) Observe the mono scope screen on the monitor and adjust so that
the screen is vertically symmetrical using the
R
and
r
keys on
the remote controller.
5-12-12. H POS Adjustment
Adjustment Method:
1) Input mono scope signal from the NTSC pattern generator.
2) Select H POS from the FOR FACTORY MODE.
3) Observe the mono scope screen on the monitor and adjust so that
the screen is horizontally symmetrical using the
R
and
r
keys
on the remote controller.
G
0V
H
0V
I
0V