Replacement: FPC Main Assy
INSTALLATION
Place the new Sheet ACF Relay in the correct position.
Press to secure its attachment.
The guiding hole must be aligned accurately between
the Sheet ACF Relay and the PBA of the FPC Main Assy!
Peel off the protective film.
Pre-bend the FPC Main by the Guide line as shown in the
picture.