27
Mode Settings
Setting the shutter speed using the DIP switches
*1 This is an external input signal.
*2 The exposure time (Te) is determined by the
setting of the DIP switches.
For details, see page 17.
*3 Normal operation is resumed when the trigger
pulse width is 1/3 s or more. The trigger falling
edge restores external trigger shutter operation. At
this time, the 50 ms after the falling edge of the
trigger pulse is an external trigger input inhibition
area. There is no guarantee of operation for any
trigger input in this period.
T
*
4
External trigger shutter operation
Normal operation
*
3
Mode transition state
External input
inhibition area
(50 ms)
External trigger
shutter operation
Exposure time (Te)
*
2
Exposure time
(Te)
*
2
Trigger pulse width
*
3
796 H (Binning OFF)
398 H (Binning ON)
Trigger
*
1
Video out
*
5
WEN
T
*
4
2
µ
s to 250 ms
*4 The image is output at the shortest timing from the
trigger rising edge according to the DIP switch
setting. The image is output synchronized with the
WEN pulse rising edge.
*5 With the XC-HR70, a signal synchronized with
VD cycle is not output.
Note
An image is not output correctly when the next trigger
is input before the image for the previous trigger has
been output.