SERVICING NOTES
OPENING AND CLOSING OF THE MONITOR IN
AN ELECTRIC INTERRUPTION STATE
In the state of electric interruption, if a monitor is opened and
closed by force, it will became the cause of failure.
Please open and close a monitor at the time of repair after the
following procedure decomposes and removing a motor.
1) Front Panel Assy (Disassembly page 9)
2) Case (Upper) Assy (Disassembly page 10)
3) Motor Assy (Monitor Open/Close) (M701)
Note:
Follow the disassembly procedure in the numerical order given.
1
five screws (M2
×
2.3)
3
three screws (M2
×
2.3)
6
Open and close a monitor after lifting
a motor assy (monitor open/close) (M701).
motor assy (monitor open/close) (M701)
3
screw (M2
×
2.3)
2
cover
4
lug
5