5
NW-E50/E70
SECTION 2
TEST MODE
STANDING PROCEDURE
Procedure 1: Set a dry battery into NW-E50/E70, and keep the
battery lid open.
Procedure 2: In HOLD state, while pushing
Nx
and
[GROUP]
button, turn power on by closing the battery lid of
NW-E50/E70.
Procedure 3: Set HOLD state off.
After starting up test mode, the following contents can be checked.
TEST MODE
•
Nx
button
The KEY test mode is activated. All key inputs are completed,
then
Nx
button is pressed, restart. (Be aware that the
initialization is included on all key input.)
•
[MENU]
button
EL0 (blue) lights on/off.
•
[GROUP]
button
EL1 (green) lights on/off.
• -
/>
All LCD lights and ACCESS LED lights off.
•
./
+
All LCD lights and ACCESS LED lights on.
•
[VOL +]
button
BEEP turns on.
•
[VOL --]
button
BEEP turns off.
•
[ REPEAT SOUND]
button
Initialized. (Turns to the factory preset state, time, volume
setting and so on.)
The music data, files and so on in the memory are not changed.
•