14
MZ-E710
5-5-3. Vc PWM Duty (L) adjustment method
1. Set the Test mode.
2. Set the manual mode, item No. will change to 754.
LCD display
754
ChgV L XX
3. Connect a digital voltmeter to TP962 (V) on the main board
and adjust
VOL +
(voltage up) key and
VOL –
(voltage
down)key on the remote control.
Adjustment value:1.35V
Standard value:1.345 to 1.355V
MAIN BOARD
(SIDE A)
R904
C905
D902
C912
C911
R905
C906
0
4
C907
R907
C915
D903
C910
9
TP962
(V)
TP962
(V)
digital voltmeter
4. Press
key to write the adjustment value.
5-5-4. Charge voltage (H) adjustment method
1. Set the Manual mode and set the item No. to 755.
LCD display
755
ChgV H XX
2. Connect a digital voltmeter to TP962(V) on the main board
and adjust
VOL +
key (Voltage down) and
VOL –
key
(Voltage up) on the remote control.
Adjustment value:1.80V
Standard value:1.795 to 1.805V
MAIN BOARD
(SIDE A)
R904
C905
D902
C912
C911
R905
C906
0
4
C907
R907
C915
D903
C910
9
TP962
(V)
TP962
(V)
digital voltmeter
3. Press
key to write the adjustment value.
5-5-5.Current Amplifier (L) adjustment method
1. Make a solder bridge to short out TAP951 on the main board
and turn on the power.
2. Set the test mode.
3. Set the Manual mode and set the item No. to 752.
LCD display
752
ChgI L XX
4. Connect a digital voltmeter to TP959 on the main board and
adjust
VOL +
key (Voltage up) and
VOL –
key (Voltage
down) on the remote control.
Adjustment value:1.41V
Standard value:1.405 to 1.415V
MAIN BOARD
(SIDE A)
R965
R964
1
R968
C954
R959
C956
C960
IC951
1
6
7
12
24
19
18
13
TAP951
TP959
TP963
TAP952
TP959
TAP951
digital voltmeter
Note: Even when a measurement voltage doesn’t make it in the
standard value,it surely presses more than once the
VOL +
key or the
VOL –
key.
But, adjustment value is made to protect the inside of the
standard range.
5. Press
key to write the adjustment value.
6. Turm off the power and open the solder bridge on TAP951 on
the main board.
5-5-6. Current Amplifier (H) adjustment method
1. Make a solder bridge to short out TAP952 on the main board
and turn on the power.
2. Set the test mode.
3. Set the overall adjustment mode and set the item No. to 753.
LCD display
753
ChgI H XX
Summary of Contents for Walkman MZ-E710
Page 39: ...39 MZ E710 MEMO ...