background image

3

VPL-HW15

<Table 1>

<Table 2>

Remarks

Item Number

Data

Item

Upper byte

Lower byte

Data

Upper byte

Lower byte

Film Mode

00h

1Fh

Off

0000h

Set/Get

Auto1

0001h

Auto2

0002h

Gamma Correction

00h

22h

Off

0000h

Gamma 1

0001h

Gamma 2

0002h

Gamma 3

0003h

Gamma 4

0004h

Gamma 5

0005h

Gamma 6

0006h

NR

00h

25h

Off

0000h

Low

0001h

Middle

0002h

High

0003h

Block NR

00h

26h

Off

0000h

Low

0001h

Middle

0002h

High

0003h

Mosquito NR

00h

27h

Off

0000h

Low

0001h

Middle

0002h

High

0003h

Color Space

00h

3Bh

Normal

0000h

Wide

0001h

USER GAIN RED

00h

50h

FFE2h to 001Eh (

_

30 to 30)

USER GAIN GREEN

00h

51h

FFE2h to 001Eh (

_

30 to 30)

USER GAIN BLUE

00h

52h

FFE2h to 001Eh (

_

30 to 30)

USER BIAS RED

00h

53h

FFE2h to 001Eh (

_

30 to 30)

USER BIAS GREEN

00h

54h

FFE2h to 001Eh (

_

30 to 30)

USER BIAS BLUE

00h

55h

FFE2h to 001Eh (

_

30 to 30)

Iris Sensitivity

00h

56h

Recommend

0000h

Fast

0001h

Slow

0002h

Iris Manual

00h

57h

0000h to 0064h (0 to 100)

Summary of Contents for VPL VPL-HW15

Page 1: ...VIDEO PROJECTOR VPL HW15 PROTOCOL MANUAL 1st Edition ...

Page 2: ... dürfen nur von qualifiziertem Fachpersonal ausgeführt werden Um die Gefahr eines elektrischen Schlages Feuergefahr und Verletzungen zu vermeiden sind bei Wartungsarbeiten strikt die Angaben in der Anleitung zu befolgen Andere als die angegeben Wartungsarbeiten dürfen nur von Personen ausgeführt werden die eine spezielle Befähigung dazu besitzen AVERTISSEMENT Ce manual est destiné uniquement aux p...

Page 3: ...mmands 2 1 Sub Commands 2 2 1 1 ITEM List 2 2 1 2 Infrared Remote Command Code 6 2 2 Reply 8 3 RS 232C 3 1 Connection 9 3 2 Communication Specifications 9 3 3 Communication Procedure 10 3 4 Command Block Format 11 3 4 1 Simplified Command 11 3 5 Packet Examples 12 3 5 1 Change Wide Mode to Zoom 12 3 6 AMX Device Discovery 12 ...

Page 4: ......

Page 5: ... RS 232C 1 2 Glossary of Terms Table 1 1 Glossary of Terms Terms Abbreviated Description CONTROLLER _ Command initiator such as PCs PROJECTOR _ Front projector 1 3 Protocol Stack Structure The protocol stack structure diagram is shown below Though the stack is drawn for RS 232C the follow ing portions are common Table 1 2 Common Portions in Protocol Stack Layer Name Description Sub Command Value i...

Page 6: ...Upper byte Lower byte Picture Mode 00h 02h Dynamic 0000h Set Get Standard 0001h Cinema 0002h User1 0003h User2 0004h User3 0005h Contrast 00h 10h 0000h to 0064h 0 to 100 Brightness 00h 11h 0000h to 0064h 0 to 100 Color 00h 12h 0000h to 0064h 0 to 100 Hue 00h 13h 0000h to 0064h 0 to 100 Sharpness 00h 14h 0000h to 0064h 0 to 100 Color Temp 00h 17h High 0000h Mid 0001h Low 0002h Custom1 0003h Custom2...

Page 7: ...h 26h Off 0000h Low 0001h Middle 0002h High 0003h Mosquito NR 00h 27h Off 0000h Low 0001h Middle 0002h High 0003h Color Space 00h 3Bh Normal 0000h Wide 0001h USER GAIN RED 00h 50h FFE2h to 001Eh _30 to 30 USER GAIN GREEN 00h 51h FFE2h to 001Eh _30 to 30 USER GAIN BLUE 00h 52h FFE2h to 001Eh _30 to 30 USER BIAS RED 00h 53h FFE2h to 001Eh _30 to 30 USER BIAS GREEN 00h 54h FFE2h to 001Eh _30 to 30 US...

Page 8: ...oom 0002h Zoom 0003h Full1 0007h Full2 0008h Over Scan 00h 23h Off 0000h On 0001h Screen Area 00h 24h Full 0000h Through 0001h Table 2 3 ITEM List For Setup Table 1 Table 2 Remarks Item Number Data Item Upper byte Lower byte Data Upper byte Lower byte Input 00h 01h Video 0000h Set Get S Video 0001h Input A 0002h Component 0003h HDMI1 0004h HDMI2 0005h Picture Muting 00h 30h Off 0000h On 0001h ...

Page 9: ...e lamp timer indicates 1000H return values are 03h upper byte and E8h lower byte Table 2 5 ITEM List For Infrared Remote Command Table 1 Table 2 Remarks Item Number Data Item Upper byte Lower byte Data Upper byte Lower byte Infrared Remote Command 15 bit category 17h Refer to the section 2 1 2 1 00h 00h Set Only Infrared Remote Command 20 bit category 19h Refer to the section 2 1 2 1 Table 2 6 Tab...

Page 10: ... HIGH O _ 19 CONTRAST _LOW O _ 1A COLOR HIGH O _ 1B COLOR _LOW O _ 1E BRIGHTNESS BRIGHT O _ 1F BRIGHTNESS _DARK O _ 20 HUE GREENISH O _ 21 HUE _PURPLISH O _ 22 SHARPNESS SHARP O _ 23 SHARPNESS _SOFT _ O 08 RCP _ O 09 ADJUST PICTURE TOGGLE _ O 4B COLOR SPACE TOGGLE _ O 51 PICTURE MODE DYNAMIC _ O 52 PICTURE MODE STANDARD _ O 53 PICTURE MODE CINEMA _ O 54 PICTURE MODE USER1 _ O 55 PICTURE MODE USER2...

Page 11: ...URE MUTING O _ 25 STATUS ON O _ 26 STATUS OFF O _ 29 MENU O _ 2A VIDEO O _ 2B INPUT A O _ 2C COMPONENT O _ 2E POWER ON 1 O _ 2F POWER OFF O _ 33 CURSOR O _ 34 CURSOR O _ 35 CURSOR O _ 36 CURSOR O _ 57 INPUT SELECT O _ 5A ENTER O _ 5F S VIDEO O _ 6F HDMI 1 O _ 70 HDMI 2 O _ 7B RESET 1 Send the command twice when this unit is in standby state Table 2 9 Infrared Remote Command Code For Installation C...

Page 12: ...mber Data Item Data Upper byte Lower byte ACK COMPLETE 00h 00h NAK UNDEFINED COMMAND 01h 01h SIZE ERROR 04h SELECT ERROR 05h RANGE OVER 06h NOT APPLICABLE 0Ah CHECK SUM ERROR F0h 10h FRAMING ERROR 20h PARITY ERROR 30h OVER RUN ERROR 40h OTHER COMM ERROR 50h Error description Check Sum Error A check sum error occurred Framing Error A framing error occurred Parity Error A parity error occurred Over ...

Page 13: ... TxD Transmit Data 4 N C _ 5 GND Signal Ground 6 N C _ 7 N C _ 8 N C _ 9 N C _ 3 2 Communication Specifications Full duplex communication channels Flow control not performed Start stop synchronism system Baud rate 38 4 kbps bits per second The bit configuration is defined as follows 1 START Bit 8 DATA Bits 1 PARITY Bit 1 STOP Bit EVEN Parity Total number of 1 s from D0 to D7 is an even number 8 0 ...

Page 14: ...be issued by CONTROLLER and PROJECTOR responses to it Fig 3 1 Command Sequence It is prohibited that CONTROLLER send another command before receiving the response to the previous command Since PROJECTOR executes the command before sending the return data CONTROLLER must wait a while before receiving the response The waiting time depends on the commands Approxi mate waiting time is shown below 30 t...

Page 15: ...tem list in the sections 2 1 1 and 2 1 2 02h Express data to be Reply data Data value described in the item list in the sections 2 1 1 and 2 1 2 3 4 Command Block Format There are 2 types of block format for RS 232C as shown in the Fig 1 1 In this section the block format for Simplified Command and Simplified Variable Length Command are provided 3 4 1 Simplified Command Send The block format for s...

Page 16: ...the same purpose There is WIDE MODE TOGGLE key on the infrared remote controller By using this key wide mode can be changed Issue the Infrared Remote Command for this key several times to set wide mode Zoom Packet format will make as follows Refer to the Table 2 7 for wide mode toggle START CODE A9h ITEM NUMBER 196Eh WIDE MODE TOGGLE SET GET 00h SET DATA 0000h CHECK SUM 7Fh END CODE 9Ah 3 6 AMX De...

Page 17: ... formellement la copie de quelque partie que ce soit de ce manuel ou son emploi pour tout autre but que des opérations ou entretiens de l équipement à moins d une permission écrite de Sony Corporation Das in dieser Anleitung enthaltene Material besteht aus Informationen die Eigentum der Sony Corporation sind Die Sony Corporation untersagt ausdrücklich die Vervielfältigung jeglicher Teile dieser An...

Page 18: ...Sony Corporation VPL HW15 J VPL HW15 SY VPL HW15 UC E 9 968 699 01 Printed in Japan 2009 8 22 2009 ...

Reviews: