16
VPL-EW130
4. COMMAND
Field
There are two types of COMMAND
fi
eld, which are REQUEST and RESPONSE. REQUEST command
is sent to the PROJECTOR from CONTROLLER. On the other hand, RESPONSE command is sent by
PROJECTOR as a response to the REQUEST command.
(1) REQUEST Command
COMMAND
fi
led for REQUEST has three sub
fi
elds shown as follows.
Fig. 4-7 COMMAND Filed for REQUEST
1) REQUEST
sub
fi
eld
There are only two types of request. One is the GET request to acquire the projector information and
status. The other is the SET request to modify the projector setup.
SET (00h) Used to control turning the power on/off and to control the input selector, and to change
the various setups.
GET (01h) Used to acquire the installation information, equipment status and various setup values.
2) ITEM NO sub
fi
eld
Refer to 6. of the section 4-3-2.
3) DATA LENGTH sub
fi
eld
This
sub
fi
eld shows the length in byte of the DATA
fi
eld in the SDCP packet. The maximum data
length is 128 bytes. If there is no data to be sent, its value should be 0h.
REQUEST(1)
ITEM NO(2)
DATA LENGTH(1)