10

The search for available channels finishes and the 
displayed channel is set.

Searching for Active Channels 
within a Group (Active Channel 
Scan)

You can search for channels in use within the specified 
channel group. This is useful when using more than one 
receiver in combination with a single transmitter.
Before performing this procedure, select the channel 
group.

For details, see “Setting the Receive Channel” (page 9).

1

Press the MENU button to display the RX1 or RX2 
menu, and press the + or – button to display the ACT 
SCAN screen.

2

Press and hold the SET button for 1 second or longer.

Press and hold until the channel group and “+” 
display starts flashing.

3

Press the + button.

The unit starts to scan for active channels in the 
selected channel group. When active channels are 
found, the first channel number among the active 
channels starts flashing on the display.

To display the next active channel number

Press the + button.

To cancel searching

Press the – button. The display returns to the ACT 
SCAN screen.

4

Press the SET button when the desired channel 
number starts flashing.

The search for active channels finishes and the 
displayed channel is set.

Setting the Compander Mode

Depending on the transmitter being used in conjunction 
with the unit, changing the compander mode may be 
necessary.
You can configure different compader modes for tuner 1 
and tuner 2.

• When operating in conjunction with UWP-D series 

transmitters, set the transmitters to the same compander 
mode.

• No audio will be output if the tone signal frequency is 

different due to inconsistencies in compander mode 
settings configured on the devices being used together.

1

Press the MENU button to display the RX1 or RX2 
menu, and press the + or – button to display the 
COMPANDER screen.

2

Press and hold the SET button for 1 second or longer.

The selected item starts flashing.

3

Use the + or – button to select the compander mode, 
then press the SET button.

The selected compander mode is configured.

UWP-D: 

Select this when operating in conjunction 

with Sony UWP-D series transmitters.

UWP: 

Select this when operating in conjunction with 

Sony UWP series transmitters.

WL800: 

Select this when operating in conjunction 

with Sony WRT series transmitters.

Transmitter and compander mode 
combinations

Configure the appropriate compander mode based on the 
transmitters being used.

Audio will not be output if the combination of 
transmitters and compander mode settings are not correct.

Notes

Note

Transmitter

Compander mode on 
unit

UWP-D

UWP

WL800

UWP-D series 
(UTX-B03, 
UTX-M03, 
UTX-P03, 
UTX-B03HR)

Compander 
mode: UWP-D

Yes

No

No

Compander 
mode: UWP

No

Yes

No

Compander 
mode: WL800

No

No

Yes

UWP series (UTX-B2, UTX-H2, 
UTX-P1)

No

Yes

No

WRT series (WRT-822, etc.)

No

No

Yes

Summary of Contents for URX-P03D

Page 1: ...UHF Synthesized Diversity Tuner Operating Instructions URX P03D 4 593 095 11 1 2016 Sony Corporation ...

Page 2: ...ithin a Group Clear Channel Scan 9 Searching for Active Channels within a Group Active Channel Scan 10 Setting the Compander Mode 10 Using the Infrared Communication Function 11 Adjusting the Monitor Audio Level 12 Menu Displays and Detailed Settings 12 Menu Structure and Hierarchy 12 Basic Menu Operations 13 UTILITY Menu 13 RX tuner 1 2 Menu 14 EXT IN Menu 15 Error Messages 15 Troubleshooting 16 ...

Page 3: ...on of materials Diversity reception system The unit employs a space diversity system to minimize dropouts true diversity system during one channel operation for higher stability Compatibility with Sony analog wireless microphones The built in DSP enables digital companding for high quality audio transmissions Switching to compander mode allows operation in conjunction with Sony analog wireless mic...

Page 4: ...l meter Indicates the input signal level B Peak indicator Warns of excessive input by lighting up when the signal is 3 dB below the level at which distortion begins C Group display Displays the name of the receive group that is configured D Channel display Displays the name of the receive channel that is configured Indicator display Status On green Sufficient battery level Flashing green Battery i...

Page 5: ...ck balanced output Connect one end of the supplied XLR BMP conversion output cable or the stereo mini plug BMP conversion cable here and the other end to the microphone input on a camcorder mixer or amplifier If the microphone input connector on the connected device is a stereo mini jack connect the straight BMP plug to the tuner and the L shaped stereo mini plug to the microphone input connector ...

Page 6: ... before replacing the batteries 1 Turn the power off 2 Slide the two catches inward as indicated and pull the battery compartment out 3 Insert two new AA batteries into the battery compartment with 3 and polarities in the correct orientation and close the compartment Make sure that the battery compartment is locked securely Battery level indicator When tuner 1 or tuner 2 is turned on the unit s re...

Page 7: ...g power using a USB output type AC adapter or portable power supply use a unit that satisfies the following conditions Output connector USB micro B type Rated voltage 5 V Output current 200 mA or higher Displays EXT when power is supplied from the USB connector Charging Nickel Metal Hydride Batteries You can charge nickel metal hydride batteries inserted in the unit When charging nickel metal hydr...

Page 8: ...e unit and then insert the other end into the hole on the other side Insert a pointed object such as a ball point pen between the belt clip and the unit and pry the end of the belt clip from the hole on the side of the unit Note Note Push the bottom of the belt clip to make some space between the belt clip and the unit 1 align the belt clip with the two vertical grooves on the shoe mount adapter a...

Page 9: ...splayed setting that is flashing is saved The same applies when setting other parameters The frequency indicator changes in response to the channel number The unit continues to receive even when setting the receive channel If the power supply cuts off while you are configuring settings perform the configuration procedure again from the beginning Make sure that the same channel is set on transmitte...

Page 10: ...g the compander mode may be necessary You can configure different compader modes for tuner 1 and tuner 2 When operating in conjunction with UWP D series transmitters set the transmitters to the same compander mode No audio will be output if the tone signal frequency is different due to inconsistencies in compander mode settings configured on the devices being used together 1 Press the MENU button ...

Page 11: ...nt to change to that frequency 6 Use the or button to select YES then press the SET button on the transmitter This sets the transmit channel and compander mode The infrared transmission from the unit in step 3 continues for about 10 seconds Perform steps 4 and 5 within those 10 seconds If 10 seconds have elapsed you can reestablish the infrared link using the SYNC screen on the unit Place the unit...

Page 12: ...is turned off Menu Displays and Detailed Settings Menu Structure and Hierarchy Menu structure UTILITY menu You can display the UTILITY menu from the meter screen which displays information on tuners 1 and 2 This menu allows you to configure basic settings for the unit RX1 tuner 1 menu This menu allows you to configure settings for RX1 tuner 1 RX2 tuner 2 menu This menu allows you to configure sett...

Page 13: ...justing the Monitor Audio Level page 12 Displaying the accumulated running time TIME Display the accumulated running time of the unit as a guide to total usage time The factory default setting is 00 00 Up to 99 99 can be displayed To reset the time display 1 Press and hold the SET button until the time display starts flashing 2 Press the button to display 00 00 CLR and press the SET button Pressin...

Page 14: ...nel automatically AUTO SET Automatically search for and set an available channel and start infrared transmission to the transmitter For details see Searching for available channels and configuring the channel settings via infrared communication AUTO SET page 11 Selecting the frequency band BAND Select the receive frequency band This menu is not available on Japanese and Korean models On these mode...

Page 15: ...onnector for audio inputs ASSIGN Select the connector from which to output signal inputs OUT1 Output the audio from the OUTPUT 1 connector If the connected microphone is an LR type the output will be mixed OUT1 2 L R Output the audio from both the OUTPUT 1 and OUTPUT 2 connectors If the connected microphone is an LR type L will be output from the OUTPUT 1 connector and R will be output from the OU...

Page 16: ...e transmitters are not set to the channels within the same channel group The channel plan is set so that no signal interference occurs when two or more transmitters are used simultaneously Set each transmitter to a different channel within the same channel group Adjacent channels are being used Use the channels separated by at least two channels 250 kHz Jamming radio waves are being received Set t...

Page 17: ...utput level 5 mW 16 Ω Audio input output connector 3 5 mm diameter mini jack Reception method Space diversity system true diversity system during one channel operation Local oscillator Crystal controlled PLL synthesizer Receive frequencies Models available in USA 470 MHz to 542 MHz UC14 model 566 MHz to 608 MHz and 614 MHz to 638 MHz UC30 model 638 MHz to 698 MHz UC42 model Models available in Eur...

Page 18: ...MP conversion cable 1 Battery case 1 Chinese model only Before Use 1 CD ROM 1 Warranty card 1 North American and Korean models only Design and specifications are subject to change without notice 63 2 1 2 28 4 1 1 8 82 3 1 4 Units mm inches Notes Always verify that the unit is operating properly before use SONY WILL NOT BE LIABLE FOR DAMAGES OF ANY KIND INCLUDING BUT NOT LIMITED TO COMPENSATION OR ...

Page 19: ...Sony Corporation ...