http://cxema.ru
– 24 –
KV-XG29M8J
RM-952
3-2. CONVERGENCE
Preparation :
•
Before starting this adjustment, adjust the focus, horizontal size
and vertical size.
•
Minimize the brightness setting.
•
Provide dot pattern.
(1)
Horizontal and Vertical Static Convergence
1. (Moving horizontally), adjust the H.STAT control so that the
red, green and blue dots are on top of each other at the center of
the screen.
2. (Moving vertically), adjust the V.STAT magnet so that the red,
green and blue dots are on top of each other at the center of the
screen.
3. If the H.STAT variable resistor cannot bring the red, green and
blue dots together at the center of the screen, adjust the
horizontal convergence with the H.STAT variable resistor and
the V.STAT magnet in the manner given below.
(In this case, the H.STAT variable resistor and the V.STAT
magnet influence each other, so be sure to perform adjustments
while tracking.)
Center dot
R G B
R
G
B
H. STAT VR
V. STAT
Magnet
RV702
H. STAT
RV1801
SCREEN (G2)
C6 Board
1
V. STAT
2
H. STAT VR
BMC (Hexapole)
V.STAT
DY pocket
Purity
V.STAT
BMC
Purity
3
R
R
R
R
G
G
G
G
B
B
B
B
a
a
a
b
b
b
b
R
R
G
G
B
B
a
a
b
b
b
Summary of Contents for Trinitron KV-XG29M8J
Page 43: ...http cxema ru 58 KV XG29M8J RM 952 PRINTED WIRING BOARDS C6 RGB OUT PICTURE ROTATION C6 Board ...
Page 48: ...http cxema ru ...
Page 49: ...http cxema ru ...
Page 50: ...http cxema ru ...
Page 51: ...http cxema ru ...
Page 52: ...http cxema ru ...
Page 53: ...http cxema ru ...