background image

– 28 –

KV-XG29M85

RM-952

SECTION 4

CIRCUIT ADJUSTMENTS

4-1. ADJUSTMENTS WITH COMMANDER

Service adjustments to this model can be performed using the
supplied Remote Commander RM-952.

a. ENTERING SERVICE MODE

With the unit on standby

This operation sequence puts the unit into service mode.

The screen display is :

b. METHOD OF CANCELLATION FROM SERVICE

MODE

Set the standby condition (Press 

[ P O W E R ]

 button on the

commander), then press 

[POWER]

 button again, hereupon it be-

comes TV mode.

c. METHOD OF WRITE INTO MEMORY

1) Set to Service Mode.

2) Press 

[1]

 (UP) and 

[4]

 (DOWN), to select the adjustment.

4) Press 

[MUTING]

 button to indicate WRITE on the screen.

5) Press 

[0]

 button to write into memory.

d. MEMORY WRITE CONFIRMATION METHOD

1) After adjustment, pull out the plug from AC outlet, and then

plug into AC outlet again.

2) Turn the power switch ON and set to Service Mode.

3) Call the adjusted items again to confirm adjustments were

made.

n

 

[DISPLAY]

 

n

 

5

 

n

  

VOL (+)

  

n

 

[POWER]

4-2. ADJUSTMENT METHOD

Item Number 00 of device GEO

This explanation uses H-Position as an example.

1. Select “GEO 00 HPS” with the 

1

 and 

4

 buttons.

2. Raise/lower the data with the 

3

 and 

6

 buttons.

3. Select the optimum state. (The standard is 1F for PAL

reception.)

4. Write with the 

[MUTING]

 button. (The display changes to

WRITE.)

5. Execute the writing with the 

-

 button. (The WRITE

display will be changed to red color while excuting, and

back to SERVICE.)

Example on screen display :-

1

4

Select the adjustment item.

3

6

Raise/lower the data value.

[MUTING]

Writes.

 

-

Executes the writing.

7

-

All the data becomes the values in memory.

8

-

All user control goes to the standard state.

5

-

Service data initialization (Be sure not to use

usually.)

2

-

Copy and write all data.

[MUTE]

-

Write 50Hz adjustment data to 60Hz, or vice

versa.

Use the same method for all Items. Use 

1

 and 

4

 to select the

adjustment item, use 

3

 and 

6

 to adjust, write with 

[MUTING]

,

then execute the write with 

-

.

Note

 : 1. In 

[WRITE]

, the data for all items are written into

memory together.

2. For adjustment items that have different standard

data between 50Hz or 60Hz, be sure to use the
respective input signal after adjustment.

PAL,SECAM:50
NTSC           :60

00

HPS

1C

SERVICE

Data

Mode

Item 

Name

Item No

Software version

Suffix No
(OEM Code)

Total Power-On time (hours)

p

Marking of new NVM

GEO

1.0C

59

7F

000A

0

626S

Device 

Name

50

1F

SERVICE 50

HPS

Adjusted with 

[3]

 

and 

[6]

 buttons.

GREEN

Write with 

[MUTING]

Write executed with 

[0]

GEO

00

7F

0

000A

59

626S 1.0C

GREEN

1F

WRITE

50

HPS

GEO

00

7F

0

000A

59

626S 1.0C

1F

SERVICE 50

HPS

RED
The WRITE display
then the display
returns to green
SERVICE

GEO

00

7F

0

000A

59

626S 1.0C

Reviews: