![Sony TRINITRON KV-PG21P10 Service Manual Download Page 21](http://html.mh-extra.com/html/sony/trinitron-kv-pg21p10/trinitron-kv-pg21p10_service-manual_1330311021.webp)
– 21 –
KV-PG21P10
RM-952
No NICAM
1 = NICAM search is disable in any TV system, 0 = NICAM search operates
US ST
(Reserved for NTSC model)
1 V-Curve
1 = using common volume curve for every mode and every TV system
(for monaural model)
0 = another volume curve available for video mode and M system
XTAL SEL
00 = only 4.43 XTAL
01 = only 3.58 XTAL
10 = not used
11 = both 4.43 and 3.58 XTAL
Other optional function will be enabled if the corresponding bit is set to 1.
No Bal.
1 = no balance in analog select items, 0 = balance included
(for AV stereo model)
SPC SOUND
1 = Space Sound available, 0 = not available
Korean ST
(Reserved for NTSC model)
H.K. Bil.
1 = NICAM bilingual available (No NICAM stereo), 0 = not available
(for monaural model)
Other optional function will be enable if the corresponding bit is set to 1.
No. 50 OP3
Item
KV-PG21P10
SECAM
1
HDEV
0
US ST
0
1 V-Curve
0
XTAL SEL
1
1
No. 4F OP2
No NICAM
0
2nd Lang.
1
Item
KV-PG21P10
H.K. Bil.
0
No Bal.
0
Auto TV Sys.
0
SPC SOUND
0
PIC Rot.
0
Thai Bil.
0
Korean ST
0
VM
0
Summary of Contents for TRINITRON KV-PG21P10