– 19 –
FLYBACK TRANSFORMER (T801)
Focus
3-3. FOCUS ADJUSTMENT
Adjust FOCUS control on the flyback transformer for the best
focus.
Item
number
37
39
3A
3B
3C
Adjustment
item
SBR
GDR
BDR
GCF
BCF
Note
SUB-
BRIGHTNESS
G. Drive
B. Drive
G. CUT-OFF
B. CUT-OFF
Standard DATA
1F
2C
2C
07
07
b. METHOD OF CANCELLATION FROM SERVICE
MODE
Set the standby condition (Press POWER button on the
commander), then press POWER button again, hereupon it be-
comes TV mode.
c. METHOD OF WRITE FOR MEMORY
1) Set to Service Mode.
2) Press
1
(UP) and
4
(DOWN), select an item of adjustments.
3) Press MUTING button indicate WRITE (RED) on screen.
4) Press
` º
button to write into memory.
a. AN ITEM OF ADJUSTMENT
d. MEMORY WRITE CONFIRMATION METHOD
1) After adjustment, pull out the plug from AC outlet, and then
plug into AC outlet again.
2) Turn the power switch ON and set to Service Mode.
3) Call the adjusted items again to confirm adjustments were made.
SERVICE
MUTING
07
DATA
LCP
Adjustment Item
09
Item number
WRITE
07
LCP
09
0
Executes the writing