![Sony TRINITRON KV-DX29K90B Service Manual Download Page 7](http://html.mh-extra.com/html/sony/trinitron-kv-dx29k90b/trinitron-kv-dx29k90b_service-manual_1330951007.webp)
– 6 –
KV-DX29K9H/KV-DX29K9H/B/DX29K90B/DX29K90L
RM-1006
RM-1006
RM-1006
RM-1006
4.
Self-diagnosis screen displays
•
In cases of malfunctions where it is not possible to determine the symptom such as when the power goes off occasionally or when
the screen disappears occasionally, there is a screen display on whether the malfunction occurred or not in the past (and whether
the detection circuit operated or not) in order to allow confirmation.
<Screen Display Method>
•
Quickly press the remote command button in the following order from the standby state.
5.
After the self-diagnosis operation
•
The results display is not automatically cleared. In case of repairs and after repairs, check the self-diagnosis screen and be sure
to return the results display to “ 0 ”.
•
If the results display is not returned to “ 0 ” it will not be possible to judge a new malfunction after completing repairs.
<Method of Clearing Results Display>
<Method of Ending Self Diagnosis Screen>
•
When ending the self-diagnosis screen completely, turn the power switch OFF on the remote commander or the main unit.
˘
Be aware that this differs from the method of
entering the service mode ( + ).
b
b
b
5
–
• "G" : OK, "NG" : DETECTS ONCE OR MORE
• THE 10 DIGITS OF NUMERALS ARE FOR CHECKING,
NO RELATION TO DIAGNOSIS.
• 101 : NO LED BLINKING FOR WDT.
"0" : NUMBER OF DETECTION.
Self-diagnosis screen display
1. Power off (Set to the standby mode)
2.
b
5
b
+
b
(Service Mode)
3. Channel 8
b