— 22 —
KV-34FS12T
5-1. SETTING THE SERVICE ADJUSTMENT MODE
1. Standby mode (power off).
2. Press
Display
Channel 5
Sound volume
Power
+
on the Remote Commander (press each button within a
second).
Service Adjustment Mode On
1. The CRT displays the item being adjusted.
2. Press
or
on the Remote Commander to select an item.
3. Press
or
on the Remote Commander to change the data.
4. Press
then
to save into the memory.
Service Adjustment Mode Memory
service defl hsiz
16
ntsc
vchp 00000000 00000000
Category
Display
Item
Mode
Item
Data
Signal
Type
write
1. Press
then
on the Remote Commander to
initialize.
service defl hsiz
16
ntsc
vchp 00000000 00000000
Category
Display
Item
Mode
Item
Data
Signal
Type
write
2. Turn set off then on to exit Service Adjustment Mode.
SECTION 5
CIRCUIT ADJUSTMENTS
Carry out Step 1 when adjusting
IDs 0–6 and when replacing
and adjusting IC003.
5-2. MEMORY WRITE CONFIRMATION METHOD
1. After adjustment, remove the power plug from the AC outlet,
then plug it in again.
2. Turn the power switch ON and set to service mode.
3. Call the adjusted items again to confirm they were adjusted.
5-3. ADJUSTMENT BUTTONS AND INDICATORS
ELECTRICAL ADJUSTMENTS BY REMOTE COMMANDER
Use the Remote Commander (RM-Y168) to perform the circuit adjustments in this section.
NOTE: Test Equipment Required:
• Pattern generator
• Frequency counter
• Digital multimeter
• Audio oscillator
RM-Y168
MUTING
POWER
DISPLAY
1
4
8
3
5
6
ENTER
VOLUME
更多难得资料请到江南家电维修论坛免费下载!
http://bbs.520101.com