— 13 —
KV-29FS100/29FV300/34FS100/
34FV250/38FV250
2-2. CONVERGENCE
Preparation:
• Perform FOCUS, V. LIN and V. SIZE adjustments.
• Set BRIGHTNESS control to minimum.
• Input dot pattern.
B
G
R
Center dot
V.STAT magnet
RV701 V.STAT
R G B
2-2-1. VERTICAL AND HORIZONTAL STATIC
CONVERGENCE
1. Adjust V. STAT magnet to converge red, green and blue dots in the
center of the screen (Vertical movement).
Tilt the V. STAT magnet and adjust static convergence to open or
close the V. STAT magnet.
2. When the V. STAT magnet is moved in the direction of arrow a and b,
red, green, and blue dots move as shown below:
B
R
G
B
R
G
R G
B
G
R
B
G
B
R
B G
R
1
2
3
a
b
a
b
b
b
a
a
b
b
a
b
a
b
2-2-2. OPERATION OF BMC (HEXAPOLE)
MAGNET
The respective dot positions resulting from moving each magnet interact,
so perform adjustment while tracking.
1 Use the V.STAT tabs to adjust the red, green, and blue dots so they
line up at the center of the screen (move the dots in a horizontal
direction).
R G
B
R G B
R
G B
R G B
R G B
R G B
2-2-3. Y SEPARATION AXIS CORRECTION
MAGNET ADJUSTMENT
1. Input cross-hatch pattern, adjust PICTURE to minimum and
BRIGHTNESS to normal.
2. Adjust the deflection yoke upright so it touches the CRT.
3. Adjust so that the Y separation axis correction magnet on the neck
assembly is symmetrical from top to bottom (open state).
BMC MA
GNET
PURITY
V.STAT
4. Return the deflection yoke to its original position.
Summary of Contents for TRINITRON KV-29FS100
Page 32: ... 32 KV 29FS100 29FV300 34FS100 34FV250 38FV250 ...
Page 33: ... 33 KV 29FS100 29FV300 34FS100 34FV250 38FV250 A BOARD WAVEFORMS ...
Page 34: ... 34 KV 29FS100 29FV300 34FS100 34FV250 38FV250 ...
Page 35: ... 35 KV 29FS100 29FV300 34FS100 34FV250 38FV250 ...
Page 36: ... 36 KV 29FS100 29FV300 34FS100 34FV250 38FV250 ...
Page 37: ... 37 KV 29FS100 29FV300 34FS100 34FV250 38FV250 ...