KV-28WF3/32WF3
27
V SIZE
V POS
V LIN
H SIZE
H PIN CUSH
H TILT
H UP COR
H LOWER COR
AFC V BOW
AFC V ANGLE
H POS
DEFLECTION SYSTEM ADJUSTMENT
1.
Enter into the service mode and select ‘Deflection cont’. The
‘Deflect cont. SDA9361’ adjustment menu will be displayed.
2.
Select and adjust each item in order to get an optimum image.
Item No
Adjustment item
Data Amount
1
V Size
Adj
2
V Centre
Adj
3
V Linearity
Adj
4
S Correction
Adj
5
H Size
Adj
6
Pin Amp
Adj
7
Up Corner Correction
Adj
8
Low Corner Correction
Adj
9
V Bow
Adj
10
Pin Phase
Adj
11
V Angle
Adj
12
HDE
ON
13
VR
0
14
RABL
ON
15
Blk Dis
OFF
16
2FH 2xLine Freq
ON
17
Stand-by Mode
OFF
18
Vertical
ON
19
BSE Blk Select
OFF
20
SSE Start Scan
OFF
21
SRSE Start Red Scan
OFF
22
GBE Guard Board
OFF
23
STE Scan time table
OFF
24
NSA Self Adaption
ON
25
V EHT comp
28” = 111
32” = 90
26
H EHT comp
28” = 85
32” = 90
27
H Centre
32
28
PWM Start
0