![Sony TC-KB920S Service Manual Download Page 10](http://html.mh-extra.com/html/sony/tc-kb920s/tc-kb920s_service-manual_397380010.webp)
– 10 –
SECTION 4
ELECTRICAL ADJUSTMENTS
Note:
The adjustment should be performed in the order given in the ser-
vice manual. As a rule, adjustments about playback should be per-
formed before those about recording.
The adjustments should be performed before for both L-CH and R-
CH.
• Switches and controls should be set as follows unless otherwise
specified.
DOLBY NR, MPX FILTER switch: OFF
MONITOR switch: Tape
• Standard Record:
Deliver the standard input signal level to the input jack and set
the REC LEVEL control to obtain the standard output signal
level.
– Record Mode –
Standard Input Level
input terminal
LINE IN
source impedance
10 k
Ω
input signal level
0.5 V (–3.8 dB)
Standard Output Level
output terminal
LINE OUT
load impedance
47 k
Ω
output signal level
0.5 V (–3.8 dB)
Test Tape
Type
Signal
Used for
P-4-A100
10 kHz, –10 dB
Azimuth Adjustment
P-4-L300
315 Hz, 0 dB
Playback Level Adjustment
WS-48B
3 kHz, 0 dB
Tape Speed Adjustment
+
–
set
47 k
Ω
LINE OUT
LINE IN
600
Ω
10 k
Ω
attenuator
AF OSC
level meter
Record/Playback Head Azimuth Adjustment
Procedure:
1. Mode: FWD playback
2. Turn the adjustment screw for the maximum output levels. If
these levels do not match, turn the adjustment screw until both
of output levels match together within 1 dB.
3. Phase Check
Mode: playback
4. After the adjustment, lock the screw with locking compound.
Adjustment Location: Record/Playback head
+
–
set
47 k
Ω
LINE OUT
level meter
Test tape
P-4-A100
(10 kHz, –10 dB)
Screw
position
L-CH
peak
within
1dB
output
level
L-CH peak
R-CH peak
within
1dB
angle
R-CH
peak
+
–
V
H
+
–
Screen pattern
Good
Wrong
in phase 45
°
90
°
135
°
180
°
LINE OUT
set
R-CH
L-CH
47 k
Ω
47 k
Ω
oscilloscope
test tape
P-4-A100
(10 kHz, –10 dB)
Adjustment screw
0 dB=0.775 V