STR-DE915/TA-V909/VE910
2-11. SCHEMATIC DIAGRAM — AMP, POWER SUPPLY SECTION —
Note :
• All capacitors are in
µ
F unless otherwise noted. pF:
µµ
F 50WV or
less are not indicated except for electrolytics and tantalums.
• All resistors are in
Ω
and 1/4W or less unless otherwise specified.
•
: non flammable resistor.
•
: panel designation.
•
B+
: B+ Line.
•
B–
: B– Line.
• Voltage is measured with respect to ground under no-signal
conditions.
• Voltages are reference value measured by a VOM (10M
Ω
/V).
• Signal path
: FM
: CD (ANALOG)
• Abbreviation
CND
: Canadian
CH
: Chinese
The components identified by
mark
!
or dotted line with mark
!
are critical for safety.
Replace only with part number
specified.
Les composants identifiés par
une marque
!
sont critiques
pour la sécurité.
Ne les remplacer que par une
pièce portant le numéro spécifié.