8
Location and Function of Parts and Controls
0
EXT IN-1 MIC/LINE (external 1 microphone/
line signal input) connectors and MIC/LINE
switch
EXT IN-1 MIC/LINE connectors
Accept an external audio signal.
MIC connector (XLR type):
Connect a rostrum
or conference hall microphone.
Note
When you use a connecting cable with an XLR
connector, pin No.1 and the case (metal part) of
which are connected, noise may be picked up.
LINE connector (phono jack):
Connect to
external equipment such as audio equipment.
MIC/LINE switch
Selects the signal input to the EXT IN-1 connector.
MIC:
Set the switch to this position when a
microphone is connected.
LINE:
Set the switch to this position when an item
of audio equipment is connected.
! ¡
LINE OUT (line output) connectors
(phono jacks)
Supply the signal from the chairman’s unit/
delegate’s unit, that from the rostrum or conference
hall microphone. There are two connectors. Use
these connectors when recording the output to a
tape recorder or when sending the line output to
the monitor system transmitter by means of an
infrared or induction-based system.
!™
TELEPHONE COUPLER
connector (6-pin
multi-connector)
Connect to the SX-T100 telephone coupler (not
supplied).
!£
EXT IN-2 MIC/LINE (external 2 microphone/
line signal input) connectors and MIC/
LINE (microphone/line signal select)
switch
EXT IN-2 MIC/LINE connectors
Input an external audio signal.
MIC connector (phone jack):
Connect a rostrum
or conference hall microphone.
LINE connector (phono jack):
Connect to
external equipment such as audio equipment.
MIC/LINE switch
Selects the signal input to the EXT IN-2 connector.
MIC:
Set the switch to this position when a
microphone is connected.
LINE:
Set the switch to this position when an item
of audio equipment is connected.
!¢
DELEGATE’S/CHAIRMAN’S UNIT
connectors (20-pin multi-connectors)
Connect to the SX-C100A/SX-C150/SX-D100A/
SX-D150 Chairman’s Unit/Delegate’s Unit. The
same signal is output from four connectors. Up to
15 SX-C100A/D100A units can be connected to
each of the four connectors. Thus, up to 60 SX-
C100A/SX-C150/SX-D100A/SX-D150 units can
be connected.
!∞
y
(signal ground) terminal
Ground if necessary.
!§
AC IN (AC power input) connector
Connect the unit to an AC power source by means
of the supplied AC power cord.
Summary of Contents for SX-C100A