41
One-shot Recording
One-shot input
Interval (ex. 1 minute)
To start one-shot recording immediately
Press REC
z
again or short-circuit the 1 SHOT IN
and COM terminals
to 1 SHOT IN
to COM
Recording the number of fields you set.
(ex. 4 fields)
1
Turn on the power of the equipment to be used.
2
Set the recording speed in this display window to
“000” by pressing REC/PLAY SPEED (MENU) +
or –.
3
Press MENU and MENU
V
until “3” of the MAIN
MENU flashes on the monitor screen.
4
Press MENU
B
.
The ALARM SET/1 SHOT REC menu appears.
5
Press MENU
V
to move the flashing to the setting
of REC FIELD.
6
Press MENU + or – to specify REC FIELD (the
number of fields) to be recorded during one-shot
recording and then press MENU
V
.
7
Press MENU + or – to set the one-shot time in
INTERVAL.
8
Press SEARCH/AUDIO ON to return to the
normal display.
Aside from long-term recording in time-lapse mode,
this unit is capable of one-shot recording, which has
applications with data files and animation.
To set the desired interval for one-shot
recording
When you short-circuit the 1 SHOT IN and COM
terminals, you can set the desired interval up to three
minutes. (However, the number of fields specified in
step 6 is recorded.)
In step 7 of the operations, set INTERVAL to the same
and longer interval than the one made by short-
circuiting 1 SHOT IN and COM terminals.
In step 9, short-circuit the 1 SHOT IN and COM
terminals after you have pressed REC
z
to start
recording.
A1
ALARM SET
ALARM MODE
1SHOT REC
REC FIELD
INTERVAL
0 1
1 m i n
ALARM SPEED
SP 2H
2 0 s
ALARM DURATION
ALARM DATA REC
TAPE END WARN.
CLOG DETECTION
SERIES REC
SELECT :
DATA SET :
+
/
–
RETURN : MENU
<
NEXT PUSH
>
OFF
COUNTER
ON
OFF
9
2-7
1
8
9
Press REC
z
.
The unit enters the recording pause mode. After
the interval to be set passes, one-shot recording
starts.