CC FILTER
<CC FILTER>
S02 TOP
A: 3200
B: 3200
C: 4300
D: 6300
E: 8000
When the CC filter is replaced with a nonstandard color temperature conversion filter, change this setting. However,
when the CC filter is replaced with a filter without color temperature conversion, such as cross filter, set 3200K. This
setting is a reference for color temperature display and the color temperature control function.
MANUAL RPN
<MANUAL RPN>
S03 TOP
RPN CH SELECT : R
RPN CURSOR : OFF
CURSOR H POS. : 1006
CURSOR V POS. : 575
CURSOR JUMP : CURR
RPN WIDTH : 1
RECORD RPN : EXEC
DELETE RPN : EXEC
FIELD/FRAME : FIELD
MONITOR SEL : YPbPr
The MANUAL RPN menu is used for manual RPN compensation. For details, refer to
.
RPN MANAGE
<RPN MANAGE>
S04 TOP
RPN ALL PRESET : EXEC
AUTO CONCEAL : EXEC
APR AT ABB : ON
The RPN MANAGE menu is used for RPN compensation setting and management. For details, refer to
Performing Automatic RPN Detection Effectively”
.
HDC4300
8-5