6.
Record the RPN compensation adjustment data.
ITEM: RECORD RPN → EXEC
A message “RECORD DATA OK? YES → NO” is displayed.
7.
After confirming that RPN disappears, select(turn the knob) "YES" by rotary encoder and confirm(press the button).
Message “COMPLETE” is displayed, the compensation data is recorded.
5-6-4.
Performing Automatic RPN Detection Effectively
Preparation
• Lens iris→ CLOSE
• Setting for MSU
BARS button → OFF (dark)
SHUTTER button → OFF (dark)
Procedure
1.
Open the following page by camera setup menu.
MENU: SERVICE
PAGE: RPN MANAGE
<RPN MANAGE>
S04 TOP
RPN ALL PRESET : EXEC
AUTO CONCEAL : EXEC
APR AT ABB : ON
2.
Execute the automatic compensation of RPN.
ITEM: AUTO CONCEAL → EXEC
HDC4300
5-33