6.
Store the reference file.
(Refer to the
Setting after Adjustment
• Setting for MSU
MASTER GAIN → 0
TEST 1 button → OFF (dark)
KNEE OFF button → OFF (lit)
5-4-11. White Clip Level Adjustment
Equipment: Waveform monitor (R, G, B)
Test Point: SDI 1 connector
Preparation
• Setting for MSU
MASTER GAIN → 12
TEST 1 button → ON (lit)
Procedure
1.
Operate the control panel of MSU, and set as follows.
(1) PAINT button → ON (lit)
(2) Touch panel operation: (Page 2) → [White Clip]
2.
Adjust the levels A to desired level for R, G and B respectively.
To adjust all levels for R, G and B simultaneously, adjust them using Master.
• Adjustment item : [R], [G], [B], [Master]
• Reference value : A = 756 mV
A
3.
Store the reference file.
(Refer to the
Setting after Adjustment
• Setting for MSU
MASTER GAIN → 0
TEST 1 button → OFF (dark)
5-4-12. File Store
After adjustments described in
“5-4. Video System Level Adjustment”
are completed, be sure to store the reference file.
HDC4300
5-26