4-7
SSC-DC132P/134/134P/138P
3. Press the CHANGE DATA button to ensure the
measured voltage is within the specified value range.
Subject
All white pattern
Measurement point
Relay Tool TP2 (A/D IN)
Equipment
Oscilloscope (AC 200 mV, 10
µ
s)
Display Mode
5 A
Specification
860
±
40 mV
4-4-7. AGC MAX Adjustment
1.
Press the STEP FORWARD button of the commander
twice.
The mode indicator will display “5C”.
2.
Install the ND filter (6.25 %).
3.
Keep the lens iris at 4-4-6. 2.
4.
Press the CHANGE DATA button to ensure that the
measured voltage is within the specified value range.
Subject
All white pattern
Measurement point
VIDEO OUT image level
Equipment
Waveform Monitor
Display Mode
5C
Specification
95
±
3 IRE (NTSC)
678
±
20 mV (PAL)
A/D IN
Image Level
4-4-8. WB (3200K preset) Adjustment
1.
Press the STEP FORWARD button of the commander
once.
The mode indicator will display “50”.
2.
Remove the ND filter. Adjust the lens iris so that the
VIDEO OUT image level is set at 65
±
3 IRE (NTSC)
or 455
±
20 mV (PAL).
Subject
All white pattern
Measurement point
Image level of VIDEO OUT
Equipment
Waveform Monitor
Display Mode
50
Specification
65
±
3 IRE (NTSC)
455
±
20 mV (PAL)
3.
Alternately switch the mode between “50” and “51” by
pressing the MODE DISPLAY CHANGE button, and
while doing so, press the CHANGE DATA button so
that the white bright spot is placed over the origin of
the vectorscope.
Subject
All white pattern
Measurement point
VIDEO OUT white bright spot
Equipment
Vectorscope
Display Mode
50, 51
Specification
The white bright spot is placed
over the origin of the vectorscope.
IRIS OUT