STR-KSL50
• DSP Test Mode Items
Items
SWAP
DSP Version
DSP communication
Bass Management
Main Speaker cut off Freq.
LFE cut off Freq.
Co-ef. Read Address
Co-ef. Read Data
Co-ef. Write Address
Co-ef. Write Data
SRAM
Total operation time
Longest Power ON time
Output time less than
–50dB volume
Output time less than
–40dB volume
Output time less than
–30dB volume
Output time less than
–20dB volume
Output time less than
–10dB volume
Output time less than
0dB volume
Protector count value
Fuse open count value
EEPROM CONDITION
Remark
Selection of setting
output channels
Checking communication
between DSP and microcom
Checking communication
between DSP and SRAM
Four large charactors are
hour. Two small charactors
are minutes.
0 to 255
Description
Normal channel output
Left input
t
Front Left, Surround Left, Center channel output
Right input
t
Front Right, Surround Right, Sub Woofer channel output
Left input
t
Center channel output
Right input
t
Sub Woofer channel output
Left input
t
Surround Left channel output
Right input
t
Surround Right channel output
“DSPV XXX” is displayed. Three large charactors are the DSP version
that is being used.
When this item is selected the message will be displayed “ OK ” if the
checking is correct. “ ERROR ” will be displayed in a case of an error.
“SUR-NORM” is displayed.
“EQ-NORM” is displayed.
“DLY-NORM” is displayed.
“BM-NORM” is displayed.
Not used for service “BM. AUTO” is displayed.
Not used for service “MAIN 120 Hz” is displayed.
Not used for service “LFE 120 Hz” is displayed.
Not used for service “RA. XXXXX” is displayed.
Not used for service “RD. XXXXXX xx” is displayed.
Not used for service “WA. XXXXX” is displayed.
Not used for service “WD. XXXXXX xx” is displayed.
“ RAMC. OFF ” will be displayed in a case of no checking.
By pressing Cursor button the checking starts.
“ RAMC. PASS ” will be displayed if the checking is good.
“ RAMC. NG ” will be displayed if an error occurs.
“TTL-XXXX xx” is displayed.
“LNG-XXXX xx” is displayed.
“V50-XXXX xx” is displayed.
“V40-XXXX xx” is displayed.
“V30-XXXX xx” is displayed.
“V20-XXXX xx” is displayed.
“V10-XXXX xx” is displayed.
“V00-XXXX xx” is displayed.
“PROT XXX” is displayed.
“FUSE XXX” is displayed.
“E- XXXX” is displayed.
S RST
t
Super Reset : first time use EEPROM or test pattern
corrupted
FAIL
t
EEPROM read / write with microcom has problem
V CHG
t
Software version change
D CHG
t
Destination / model change
CLEAR
t
Back up data initialize
NORM
t
Normal AC on
Function
NORM
ALL
C SW
SLSR
–
–
–
–
–
–
–
–
–
–
–
–
–
OFF
ON
–
–
–
–
–
–
–
–
–
–
–