ELECTRICAL ADJUSTMENT
[IDLING CURRENT ADJUSTMENT]
Measuring Instrument:
Digital voltmeter
Adjustment Procedure:
Adjust the respective adjustment elements so that the voltage (absolute value) across the corresponding
testpoints satisfies the specification.
Specification
4.0mV
±
0.5mV
Channel
FRONT L
FRONT R
CENTER
SURROUND
SURROUND
SURR BACK
Test point
TP501
TP551
TP601
TP701
TP751
TP651
Adjustment element
RV501
RV551
RV601
RV701
RV751
RV651
Adjustment Location:
TP501
RV501
TP601
RV601
RV701
TP751
TP651
TP701
VR751
VR651
TP551
RV551
[POWER AMP BOARD]
[OSD ADJUSTMENT]
Measuring Instrument:
frequency counter
Procedure:
1. Connect the frequency counter to check connector (TP201) of
the S VIDEO board.
2. Connect between Pin
3
to Pin
4
of TP201 by lead wire.
3. Adjust the respective adjustment element so that the frequency
counter read specification.
Adj.
MODEL
Adjustment
element
CT202
(CLOCK BOARD)
CT201
(CLOCK BOARD
measurement
point
Specification
I
II
DA3ES, DA5ES
VA555ES
CT203
(S-VIDEO BOARD)
CT204
(S-VIDEO BOARD)
NTSC
PAL
TP201
Pin
1
TP201
Pin
2
3.579545MHz
±
50Hz
7.20MHz
±
0.01MHz
4. After check, remove the lead wire connected in step 2.
Adjustment Location:
[S-VIDEO BOARD]
CT203
CT204
TP201
1
4
[CLOCK BOARD]
CT202
CT201
+
–
frequency counter
S- VIDEO
BOARD
Shorting
TP201
1
4
4.433618MHz
±
50Hz
3.57954MHz
±
50Hz
All models