17
HCD-DX50/RG80
FM Tuned Level Adjustment
Procedure:
1.
Supply a 98 MHz signal at 28 dB from the ANTENNA terminal.
2.
Tune the set to 98 MHz.
3.
Adjust RV11 to the point (moment) when the TUNED indicator
will change from going off to going on.
Adjustment Location:
MAIN board
Null Adjustment
Procedure:
1.
Supply a 98 MHz signal at 60 dB from the ANTENNA terminal.
2.
Tune the set to 98 MHz.
3.
Measure voltage between pin 22 and pin 3 of IC11. Adjust
T11 until the voltage becomes 0 V.
Adjustment Location:
MAIN board
Adjustment Location
[MAIN BOARD]
(Component Side)
FM RF SIGNAL GENERATOR
75
Ω
coaxial
Carrier frequency : 98 MHz
Modulation : AUDIO 1 kHz, 75 kHz
deviation (100%)
Output level : 28 dB (at 75
Ω
open)
FM ANTENNA terminal
(TM1)
set
FM RF SIGNAL GENERATOR
75
Ω
coaxial
Carrier frequency : 98 MHz
Modulation : AUDIO 1 kHz, 75 kHz
deviation (100%)
Output level : 60 dB (at 75
Ω
open)
FM ANTENNA terminal
(TM1)
set
CD SECTION
Note :
1. CD Block is basically designed to operate without adjustment.
Therefore, check each item in order given.
2. Use LUV-P01 (4-999-032-01) unless otherwise indicated.
3. Use an oscilloscope with more than 10M
Ω
impedance.
4. Clean the object lens by an applicator with neutral detergent
when the signal level is low than specified value with the
following checks.
S-Curve Check
Procedure :
1. Connect an oscilloscope to TP (FEO).
2. Connect between TP (FEI) and TP (DVC) ( 1.65 V) by lead
wire.
3. Turn Power switch on.
4. Load a disc (LUV-P01) and actuate the focus search. (In
consequence of open and close the disc tray, actuate the focus
search)
5. Confirm that the oscilloscope waveform (S-curve) is
symmetrical between A and B. And confirm peak to peak level
within 2
±
0.5 Vp-p.
6. After check, remove the lead wire connected in step 2.
Note :
• Try to measure several times to make sure than the ratio
of A : B or B : A is more than 10 : 7.
• Take sweep time as long as possible and light up the
brightness to obtain best waveform.
RF Level Check
Procedure :
1. Connect an oscilloscope CH1 to TP (RFDC) and CH2 to TP
(RFAC).
2. Turn Power switch on.
3. Load a disc (LUV-P01) and playback.
4. Confirm that oscilloscope waveform is clear and check if RF
signal level is correct or not.
BD board
Oscilloscope
TP(FEO)
TP(DVC)
T11
RV11
RV351
RV354
RV304
RV303
RV302
RV301
CN301
CN304
CN302
CN303
1
3
NULL
FM TUNED LEVEL
TUNER SECTION
symmetry
S-curve waveform
within 2
±
0.5Vp-p
A
B
TP(RFDC)
TP(RFAC)
BD board
oscilloscope
TP(DVC)
Summary of Contents for SS-DX50
Page 6: ...4 HCD DX50 RG80 SECTION 1 GENERAL This section is extracted from instruction manual ...
Page 7: ...5 HCD DX50 RG80 ...
Page 8: ...6 HCD DX50 RG80 ...
Page 32: ...30 30 HCD DX50 RG80 6 10 SCHEMATIC DIAGRAM AMP SECTION C505 10P C555 10P ...
Page 36: ...34 34 HCD DX50 RG80 6 14 SCHEMATIC DIAGRAM PANEL SWITCH SECTION ...
Page 42: ...40 40 HCD DX50 RG80 6 20 SCHEMATIC DIAGRAM TRANS SECTION ...
Page 71: ...69 HCD DX50 RG80 MEMO ...