– 17 –
2. RX VT Adjustment
1
The digital voltmeter connected TP5 (RX VT) to TP3 (GND).
2
Adjust the L102 for 0.8V
±
0.05V reading on the digital
voltmeter.
IC101
46
R130
C142
C141
C61
C136
TP5
TP3
R5
C4
[HAND MAIN BOARD]
(Component side)
L102
+
–
Digital
voltmeter
TP3
TP5
[HAND MAIN BOARD]