150
Pin Assignments of the REMOTE
connectors
REMOTE IN connector (common to SIU-100/
100T and SIU-RM101)
Signal level: Conforming to RS-422 standard standard
Connector specification: D-SUB 9-pin, female
Pin No.
I/O
Signal
1
—
Frame Ground
2
O
TX—
3
I
RX+
4
—
GND
5
—
NC
6
—
GND
7
O
TX+
8
I
RX—
9
—
Frame Ground
REMOTE OUT connector (SIU-RM101)
Signal level: Conforming to RS-422 standard
Connector specification: D-SUB 9-pin, female
Pin No.
I/O
Signal
1
—
Frame Ground
2
I
RX—
3
O
TX+
4
—
GND
5
—
NC
6
—
GND
7
I
RX+
8
O
TX—
9
—
Frame Ground
Default Settings of the SIU-100/
100T
Setting status
Routing: All cleraed.
(For all of outputs, no
sound)
Setting mode: in unit of
channels
+48 V: OFF for all of
channels
PAD: ON for all of
channels
Reference input level:
+10 dBu for all of
channels.
Only sync is set to ON.
Remaining items are set
to OFF.
Mode: AUTO -ST
Channel: Not assigned.
Sampling frequency: 48
kHz
Sync reference signal:
INTERNAL
Mode: STATUS mode
TH RED: 0dB
TH-GRN: - 54 dB
DMBK-R104: Sampling
converter: All of
parameters are set to
ON.
DMBK-R107: DA-88:
OFF
DMBK-R109: OUTPUT
MODE: 2Fs
WCK MODE: 1/1
ORIGIN: THRU
DESTINATION: THRU
Assignment between
scenes and programs:
Program numbers 1 to
127 are assigned to
scene numbers 1 to 127
respceively.
MIDI CH: 1
OMNI MODE: ON
IP ADDRESS:
192.168.000.002
GATEWAY:
192.168.000.254
SUBNET MASK:
255.255.255.0
NAME: (None)
PASSWORD: 1234
Mode: SL & CH
Submenues
Isolation setting
SYNC
LED DISPLAY
SLOT INFO
DO CH STATUS
MIDI
IP (Settings done
on this submenu
will not be
initialized.)
SIU-RM101
Menu
ROUTING
MIC PRE AMP
(DMBK-S101
installed in the
unit)
SCENE
PHONES
SETUP
Specifications